响应面法确定程序化间歇硬膜外推注泵参数用于分娩镇痛
本研究为双盲随机对照试验,纳入69例足月初产妇,使用响应面法(RSM)同时优化三个临床结局,估算程序化间歇硬膜外推注(PIEB)泵参数。建议设置为PIEB下次推注29.4分钟、间隔59.8分钟、容量6.2 mL,对应产妇满意度93.9%、PCEA比值0.77、临床医生推注需求0.29。
要点
- RSM估算的PIEB参数为下次推注29.4分钟、间隔59.8分钟、容量6.2 mL。
- 该设置下产妇满意度93.9%,PCEA比值0.77,临床医生推注需求0.29。
- 89%患者感觉阻滞平面在T10至T5之间,最低Bromage评分中位数为4。
核心结论
- RSM可同时估算PIEB泵参数以平衡三个临床结局,但等权重优化可能无法最大化单一结局。
研究设计与样本
- 双盲随机对照试验,纳入69例足月初产妇,ASA II级,年龄18-45岁,单胎头位,自然临产,宫口≤7 cm。
主要发现
- RSM建议PIEB下次推注29.4分钟、间隔59.8分钟、容量6.2 mL。
- 对应产妇满意度93.9%,PCEA比值0.77,临床医生推注需求0.29。
- 89%患者感觉阻滞平面在T10至T5之间,最低Bromage评分中位数为4。
关键数值与推荐
- PCEA比值理想值为1,临床医生推注理想值为0,产妇满意度视觉模拟评分(0-100)理想值≥90。
临床怎么用
- 可参考RSM估算的PIEB参数设置泵,但需注意等权重优化可能不反映患者优先需求。
局限性
- 等权重临床结局阻止最大优化,可能不反映患者优先级;样本量较小(69例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Three settings are required on a programmed intermittent epidural bolus (PIEB) pump for labor analgesia: the PIEB next bolus (PIEBnb), PIEB interval (PIEBi), and PIEB volume (PIEBv). The ideal settings for these parameters are still unknown. We hypothesized a mathematical modeling tool, response surface methodology (RSM), could estimate 3 PIEB pump parameters while balancing 3 clinically important patient outcomes simultaneously. The study objective was to use RSM to estimate PIEB settings (PIEBnb, PIEBi, and PIEBv) while maximizing maternal satisfaction, minimizing the need for clinician-administered boluses, and optimizing the ratio of delivered/requested patient-controlled epidural analgesia (PCEA) boluses simultaneously. METHODS: With institutional ethics approval, a double-blind randomized trial was completed in a tertiary care labor and delivery center. Nulliparous, English-speaking American Society of Anesthesiologists (ASA) physical status II patients aged 18 to 45 years at full term, single gestation in vertex presentation, in spontaneous labor and ≤7 cm cervical dilation were included. Patients with comorbidities, contraindications to neuraxial analgesia, using chronic analgesics, <152 cm, or body mass index (BMI) >45 kg/m 2 were excluded. After informed consent, labor analgesia was initiated using 10 mL ropivacaine 0.2% with 10 µg/mL fentanyl solution and PCEA (volume 6 mL every 10 minutes). Patients were randomized to predetermined PIEB settings. RSM identified 3 pump settings that represented a stationary point that best maximized or minimized 3 outcomes simultaneously: PCEA ratio (a ratio closest to 1), clinician bolus (optimal is 0), and maternal satisfaction (visual analog scale, 0-100, ideal response is ≥90). RESULTS: Of 287 potential participants, 192 did not meet inclusion criteria or declined to participate, and 26 were withdrawn, leaving 69 patients for study inclusion. Using RSM, the suggested PIEB settings for all the primary study outcomes were as follows: PIEBnb = 29.4 minutes, PIEBi = 59.8 minutes, and PIEBv = 6.2 mL. These PIEB settings corresponded to the following clinical outcomes: maternal satisfaction at 93.9%, PCEA ratio at 0.77, and need for clinician bolus at 0.29. The dermatome sensory score was between T10 and T5 in 89% of the patients. The median lowest Bromage score was 4. CONCLUSIONS: This novel study used a mathematical model to estimate PIEB pump settings while simultaneously maximizing 3 clinical outcomes. Equally weighted clinical outcomes prevent maximal outcome optimization and may not reflect patient priorities. Future studies or quality improvement endeavors could use RSM methodology to estimate PIEB pump settings targeting optimal values for a single clinical outcome of determined importance to parturients.
引用
- Munro A, George RB, Andreou P, et al. An Innovative Approach to Determine Programmed Intermittent Epidural Bolus Pump Settings for Labor Analgesia: A Randomized Controlled Trial. Anesth Analg. 2024. PMID: 38905148. doi:10.1213/ANE.0000000000006813
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。