文献速递气道管理

麻醉中气道相关严重事件与未遂事件:一项 критического事件报告系统的定性研究

Critical airway-related incidents and near misses in anaesthesia: a qualitative study of a critical incident reporting system.
PubMed 文献 · Br J Anaesth · 2024-06-12

该前瞻性定性研究在瑞士单中心筛选3668例气道管理操作,发现101例(2.8%)涉及严重事件,但仅1例(1.0%)被上报至 критического事件报告系统。访谈21名涉及42例事件的麻醉提供者后,揭示上报门槛高、担心可识别性等因素阻碍上报。

要点

  • 气道相关严重事件上报率极低,仅1.0%被上报。
  • 上报障碍包括担心事件及人员可识别性。
  • 建议采用国家层面匿名数据库并加强反馈文化。

核心结论

  • 需要促进匿名上报(如国家而非科室数据库)并改变文化以提高严重事件上报率。
  • 机构应确保及时反馈经验教训、后果及标准变更。
  • 持续上报和评估才能充分发挥 критического事件报告系统的潜力。

研究设计与样本

  • 前瞻性定性研究,单瑞士中心,筛选3668例气道管理操作。
  • 对涉及严重事件的麻醉提供者进行个体访谈,直至饱和(21人,涉及42/101例事件)。
  • 采用Framework方法分析访谈数据。

主要发现

  • 3668例气道管理操作中101例(2.8%)涉及严重事件。
  • 101例严重事件中仅1例(1.0%)被上报至 критического事件报告系统。
  • 访谈显示对报告系统目标看法差异大,整体上报门槛高。
  • 阻碍上报的因素包括担心事件及涉及医护人员的可识别性。

临床怎么用

  • 麻醉科应关注气道相关严重事件的上报障碍,推动匿名上报机制。
  • 机构需及时向团队反馈上报事件的经验教训和标准变更。
  • 改变文化以降低上报门槛,鼓励上报未遂事件。

局限性

  • 单中心研究,结果可能不广泛适用。
  • 仅访谈21名提供者,虽达饱和但样本有限。
  • 定性研究设计无法量化上报障碍的普遍性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Many serious adverse events in anaesthesia are retrospectively rated as preventable. Anonymous reporting of near misses to a critical incident reporting system (CIRS) can identify structural weaknesses and improve quality, but incidents are often underreported. METHODS: This prospective qualitative study aimed to identify conceptions of a CIRS and reasons for underreporting at a single Swiss centre. Anaesthesia cases were screened to identify critical airway-related incidents that qualified to be reported to the CIRS. Anaesthesia providers involved in these incidents were individually interviewed. Factors that prevented or encouraged reporting of critical incidents to the CIRS were evaluated. Interview data were analysed using the Framework method. RESULTS: Of 3668 screened airway management procedures, 101 cases (2.8%) involved a critical incident. Saturation was reached after interviewing 21 anaesthesia providers, who had been involved in 42/101 critical incidents (41.6%). Only one incident (1.0%) had been reported to the CIRS, demonstrating significant underreporting. Interviews revealed highly variable views on the aims of the CIRS with an overall high threshold for reporting a critical incident. Factors hindering reporting of cases included concerns regarding identifiability of the reported incident and involved healthcare providers. CONCLUSIONS: Methods to foster anonymity of reporting, such as by national rather than departmental critical incident reporting system databases, and a change in culture is required to enhance reporting of critical incidents. Institutions managing a critical incident reporting system need to ensure timely feedback to the team regarding lessons learned, consequences, and changes to standards of care owing to reported critical incidents. Consistent reporting and assessment of critical incidents is required to allow the full potential of a critical incident reporting system.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Pedersen TH, Nabecker S, Greif R, et al. Critical airway-related incidents and near misses in anaesthesia: a qualitative study of a critical incident reporting system. Br J Anaesth. 2024. PMID: 38866639. doi:10.1016/j.bja.2024.04.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。