文献速递产科麻醉气道管理

声门上气道装置在剖宫产全麻中的应用:范围综述与使用算法

The role of supraglottic airway devices for caesarean section under general anaesthesia. A scoping literature review with a proposed algorithm for the appropriate use of supraglottic airway devices for caesarean sections.
PubMed 文献 · Eur J Anaesthesiol · 2024-06-19

该范围综述评估了声门上气道装置(SGA)在剖宫产全麻中气道管理的证据。检索多个数据库后纳入13篇文献、共7722例患者,多数使用第二代SGA。结果显示无肺误吸病例,仅1例胃反流,7例置入失败需改气管插管(均为第一代装置)。作者提出在低误吸风险且预计困难插管的选择性患者中,第二代SGA或可耐受作为主要气道方法,并给出决策算法。

要点

  • 第二代SGA在低误吸风险且预计困难插管的剖宫产全麻患者中或可耐受。
  • 纳入文献中无肺误吸病例,仅1例胃反流,7例置入失败均使用第一代装置。
  • 作者提出基于证据的SGA使用决策算法,用于选择性患者。

核心结论

  • growing evidence suggests that second-generation SGA devices might be well tolerated as the primary airway method for caesarean section under general anaesthesia in selected patients with low aspiration risk and difficult intubation.

研究设计与样本

  • 范围综述,检索Medline、Embase、PubMed、Emcare、Cochrane Library和CINAHL,纳入英文、荷兰文和法文全文文献,排除病例报告和非剖宫产手术研究。
  • 初始检索获得815条结果,经筛选、去重及排除无关文献后,最终纳入13篇手稿进行分析。
  • 纳入文献共描述7722例患者,多数手稿使用第二代SGA装置。

主要发现

  • 7例置入失败需转为气管插管,这些病例均使用第一代SGA装置。
  • 无肺误吸病例报告,仅描述1例胃反流。

临床怎么用

  • 在低误吸风险且预计困难插管的选择性剖宫产全麻患者中,可考虑使用第二代SGA作为主要气道管理方法。
  • 作者提供了基于现有证据的决策算法,辅助临床判断SGA的使用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

This review aims to assess the published evidence on airway management with a supraglottic airway device (SGA) for general anaesthesia in patients requiring a caesarean section. Physiological changes during pregnancy can make airway management in parturients challenging. At the same time, pregnant patients are at risk of pulmonary aspiration due to hormonal and mechanical alterations. The standard airway management for parturients undergoing caesarean section is rapid sequence induction followed by tracheal intubation. Evidence exists that using second-generation SGA devices is well tolerated and effective in selected patients. In this review, we provide an overview of the existing evidence and provide an algorithm to make an evidence-based clinical decision on the use of SGA devices. An online literature search was performed in Medline, Embase, PubMed, Emcare, Cochrane Library and CINAHL. The search terms used were 'supraglottic airway', 'supraglottic airway device', 'supraglottic airway management', 'supraglottic tube', 'i-gel', laryngeal mask', 'laryngeal mask airway', 'LMA', 'SGA', 'Proseal', 'Supreme', 'obstetric surgery', 'obstetric operation', 'general anaesthesia', 'caesarean' or 'caesarean section', 'abdominal delivery'. Full-text articles in English, Dutch and French were included. Case reports and studies in which the surgery was not a caesarean section were excluded. The initial search yielded 815 results. Following screening, deduplication and removal of publications that were unrelated to the topic or did not fit the inclusion criteria, 13 manuscripts were included in our analysis. A total of 7722 patients were described in the articles included. In the majority of manuscripts, second-generation SGA devices were used. There were seven cases of failed insertion and a need for conversion to tracheal intubation; first-generation SGA devices were used in these cases. There were no cases of pulmonary aspiration, and only one case of gastric regurgitation was described. Growing evidence suggests that the use of second-generation SGA devices might be well tolerated as the primary method for securing the airway for caesarean sections requiring general anaesthesia, in selected patients with a low risk for aspiration and difficult intubation.

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Sanganee U, Jansen K, Lucas N, et al. The role of supraglottic airway devices for caesarean section under general anaesthesia. A scoping literature review with a proposed algorithm for the appropriate use of supraglottic airway devices for caesarean sections. Eur J Anaesthesiol. 2024. PMID: 38898775. doi:10.1097/EJA.0000000000002024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。