文献速递气道管理

高角度与Macintosh视频喉镜在预期困难气道成人中的随机对照试验

Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial.
PubMed 文献 · Anaesthesia · 2024-05-24

本研究为开放标签、患者盲法的随机对照试验,纳入182例预期困难气道的成人患者,比较高角度(C-MAC D-BLADE™)与Macintosh(C-MAC™)视频喉镜刀片。主要结局为声门开放百分比,高角度组中位数89%显著高于Macintosh组54%(p<0.001)。首次插管成功率分别为97%和67%,高角度组显著更优(p<0.001)。

要点

  • 在预期困难气道成人中,高角度视频喉镜刀片相比Macintosh刀片提供更好的声门视野。
  • 高角度刀片首次插管成功率显著更高(97% vs 67%)。
  • 由经验丰富的麻醉主治医师操作时,高角度刀片失败率更低。

核心结论

  • 对于预期困难气道的成人患者,由经验丰富的麻醉主治医师操作时,高角度视频喉镜刀片在声门视野和首次插管成功率方面均优于Macintosh视频喉镜刀片。

研究设计与样本

  • 开放标签、患者盲法的随机对照试验,纳入182例预期困难气道的成人患者,计划行择期耳鼻喉或口腔颌面手术。

主要发现

  • 声门开放百分比中位数(IQR[范围])高角度组为89(69-99[0-100])%,Macintosh组为54(9-90[0-100])%,p<0.001。
  • 高角度视频喉镜一线插管失败1例,Macintosh视频喉镜失败12例(13%,p=0.002)。
  • 首次插管成功率在高角度组为97%,Macintosh组为67%(p<0.001)。

关键数值与推荐

  • 主要结局为声门开放百分比,高角度组中位数89%,Macintosh组54%(p<0.001)。
  • 关键次要结局首次插管成功率,高角度组97%,Macintosh组67%(p<0.001)。
  • 一线插管失败率,高角度组1例,Macintosh组12例(13%,p=0.002)。

临床怎么用

  • 在预期困难气道的成人患者中,可优先选择高角度视频喉镜刀片以改善声门视野并提高首次插管成功率。
  • 由经验丰富的麻醉主治医师操作时,高角度刀片显示出更低的插管失败率。

局限性

  • 本研究为开放标签设计,操作者未设盲,可能引入偏倚。
  • 研究仅纳入由麻醉主治医师操作的特定手术患者,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways. METHODS: We conducted an open-label, patient-blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C-MAC D-BLADE™) or Macintosh videolaryngoscope blades (C-MAC™). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome. RESULTS: We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69-99 [0-100])% with hyperangulated videolaryngoscope blades and 54 (9-90 [0-100])% with Macintosh videolaryngoscope blades (p < 0.001). First-line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001). CONCLUSIONS: Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Köhl V, Wünsch VA, Müller MC, et al. Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial. Anaesthesia. 2024. PMID: 38789407. doi:10.1111/anae.16326

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。