解剖性与生理性困难气道对急诊气管插管首次尝试成功率的影响
基于美国国家急诊气道登记(NEAR)的回顾性观察研究,纳入2016至2018年13,938例成人急诊插管(排除心脏骤停),比较解剖性困难气道(ADA)、生理性困难气道(PDA)及两者并存与无困难气道者的首次尝试成功率。结果显示,ADA单独存在时首次尝试成功率降低(aOR 0.53),PDA单独存在时无显著差异(aOR 0.96),两者并存时进一步降低(aOR 0.44);无不良事件的首次尝试成功率在ADA、PDA及两者并存时均降低。
要点
- ADA单独存在与首次尝试成功率降低独立相关,PDA单独存在则无显著关联。
- ADA与PDA并存时首次尝试成功率最低(aOR 0.44),且无不良事件成功率亦降低。
- ADA与PDA对首次尝试成功率的交互作用未偏离相加模型。
核心结论
- 与无困难气道特征相比,ADA与首次尝试成功率呈负相关,PDA则无此关联。
- ADA、PDA及其交互作用均与无不良事件的首次尝试成功率呈负相关。
研究设计与样本
- 回顾性观察研究,使用国家急诊气道登记(NEAR)数据。
- 共19,071例插管者中13,938例纳入分析。
- 采用混合效应模型调整喉镜类型、插管者毕业后年资、创伤指征、患者年龄及站点随机效应。
主要发现
- 与无困难气道特征相比,ADA单独存在时首次尝试成功率的aOR为0.53(95%CI 0.40-0.68)。
- PDA单独存在时首次尝试成功率的aOR为0.96(95%CI 0.68-1.36)。
- ADA与PDA并存时首次尝试成功率的aOR为0.44(95%CI 0.34-0.56)。
- 无不良事件的首次尝试成功率:ADA单独aOR 0.72(95%CI 0.59-0.89),PDA单独aOR 0.79(95%CI 0.62-1.01),两者并存aOR 0.44(95%CI 0.37-0.54)。
- ADA与PDA对首次尝试成功率(有无不良事件)的交互作用无证据偏离相加模型(即非协同/相乘或拮抗)。
临床怎么用
- 急诊插管前应同时评估解剖性和生理性困难气道特征,ADA与PDA并存时首次尝试成功率最低。
- 对存在ADA或PDA的患者,应优化插管策略以提高无不良事件的首次尝试成功率。
局限性
- 回顾性观察设计,可能存在未测量混杂。
- 仅纳入使用镇静和肌松的成人急诊插管,排除心脏骤停,外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In the emergency department (ED), certain anatomical and physiological airway characteristics may predispose patients to tracheal intubation complications and poor outcomes. We hypothesized that both anatomically difficult airways (ADAs) and physiologically difficult airways (PDAs) would have lower first-attempt success than airways with neither in a cohort of ED intubations. METHODS: We performed a retrospective, observational study using the National Emergency Airway Registry (NEAR) to examine the association between anticipated difficult airways (ADA, PDA, and combined ADA and PDA) vs those without difficult airway findings (neither ADA nor PDA) with first-attempt success. We included adult (age ≥14 years) ED intubations performed with sedation and paralysis from January 1, 2016 to December 31, 2018 using either direct or video laryngoscopy. We excluded patients in cardiac arrest. The primary outcome was first-attempt success, while secondary outcomes included first-attempt success without adverse events, peri-intubation cardiac arrest, and the total number of airway attempts. Mixed-effects models were used to obtain adjusted estimates and confidence intervals (CIs) for each outcome. Fixed effects included the presence of a difficult airway type (independent variable) and covariates including laryngoscopy device type, intubator postgraduate year, trauma indication, and patient age as well as the site as a random effect. Multiplicative interaction between ADAs and PDAs was assessed using the likelihood ratio (LR) test. RESULTS: Of the 19,071 subjects intubated during the study period, 13,938 were included in the study. Compared to those without difficult airway findings (neither ADA nor PDA), the adjusted odds ratios (aORs) for first-attempt success were 0.53 (95% CI, 0.40-0.68) for ADAs alone, 0.96 (0.68-1.36) for PDAs alone, and 0.44 (0.34-0.56) for both. The aORs for first-attempt success without adverse events were 0.72 (95% CI, 0.59-0.89) for ADAs alone, 0.79 (0.62-1.01) for PDAs alone, and 0.44 (0.37-0.54) for both. There was no evidence that the interaction between ADAs and PDAs for first-attempt success with or without adverse events was different from additive (ie, not synergistic/multiplicative or antagonistic). CONCLUSIONS: Compared to no difficult airway characteristics, ADAs were inversely associated with first-attempt success, while PDAs were not. Both ADAs and PDAs, as well as their interaction, were inversely associated with first-attempt success without adverse events.
引用
- Nikolla DA, Offenbacher J, Smith SW, et al. First-Attempt Success Between Anatomically and Physiologically Difficult Airways in the National Emergency Airway Registry. Anesth Analg. 2024. PMID: 38335138. doi:10.1213/ANE.0000000000006828
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。