文献速递区域麻醉与超声疼痛医学

超声与MRI测量硬膜外间隙深度预测腰椎硬膜外类固醇注射阻力消失深度的相关性

Correlation between epidural space depth measured with ultrasound and MRI compared to clinical loss of resistance when performing lumbar epidural steroid injection.
PubMed 文献 · Reg Anesth Pain Med · 2024-12-02

MRI与临床阻力消失深度等效(平均差-0.2 cm,95%CI -0.39至-0.11),超声横切面和旁矢状斜切面测量均不等效且低估临床阻力消失深度。结论认为MRI测量优于超声用于术前评估预测临床阻力消失深度。

要点

  • MRI测量与临床阻力消失深度等效,平均差-0.2 cm(95%CI -0.39至-0.11)。
  • 超声横切面和旁矢状斜切面测量均不等效且低估临床阻力消失深度。
  • MRI与临床阻力消失深度的组内相关系数最高为0.85。

核心结论

  • MRI测量在预测腰椎硬膜外类固醇注射临床阻力消失深度方面优于超声,推荐用于术前评估。

主要发现

  • MRI与临床阻力消失深度平均差-0.2 cm(95%CI -0.39至-0.11),等效性成立。
  • 超声横切面测量与临床阻力消失深度平均差-0.98 cm(90%CI -1.8至-0.77),不等效且低估。
  • 超声旁矢状斜切面测量与临床阻力消失深度平均差-0.79 cm(90%CI -1.0至-5.9),不等效且低估。
  • MRI与临床阻力消失深度的组内相关系数为0.85,超声横切面和旁矢状斜切面分别为0.65和0.73。

临床怎么用

  • 在腰椎硬膜外类固醇注射术前,可优先采用MRI测量皮肤至后硬膜外间隙距离以预测临床阻力消失深度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This prospective study assessed the accuracy of MRI and ultrasound (US) measurements as a preprocedural assessment tool for predicting clinical loss of resistance depth (CLORD) during fluoroscopy-guided lumbar epidural steroid injections (ESIs). MATERIALS AND METHODS: Sixty patients enrolled received lumbar ESIs at an academic chronic pain clinic. The MRI measurement calculated the distance between the skin and the posterior epidural space, while US measurements included transverse and parasagittal oblique views of the interlaminar space. The epidural space measurements were compared with the CLORD during the performance of the prone epidural injections. The differences in measurements were analyzed using two one-sided tests for equivalency with a 0.5 equivalency margin. The intraclass correlation coefficients between CLORD and the imaging modalities were estimated using mixed effects models. RESULTS: MRI was equivalent to CLORD with a mean difference of -0.2 cm (95% CI -0.39 to -0.11). US transverse and US parasagittal oblique measurements were not equivalent to and underestimated CLORD with mean differences of -0.98 cm (90% CI -1.8 to -0.77) and -0.79 cm (90% CI -1.0 to -5.9), respectively. The intraclass correlation coefficients between MRI and CLORD were the highest at 0.85, compared with 0.65 and 0.73 for transverse and parasagittal oblique US views, respectively. CONCLUSIONS: MRI measurements are preferable over US for preprocedural assessment of patients receiving lumbar ESIs for predicting CLORD.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Singh N, Pritzlaff S, Bautista B, et al. Correlation between epidural space depth measured with ultrasound and MRI compared to clinical loss of resistance when performing lumbar epidural steroid injection. Reg Anesth Pain Med. 2024. PMID: 38267075. doi:10.1136/rapm-2023-105135

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。