文献速递产科麻醉心胸血管麻醉

受训者在剖宫产术中实施聚焦心脏超声的可行性

Feasibility of Focused Cardiac Ultrasound Performed by Trainees During Cesarean Delivery.
PubMed 文献 · Anesth Analg · 2024-07-15

前瞻性队列研究纳入ASA≤3、≥37周单胎、BMI<40 kg/m²且无心脏病史的择期剖宫产足月产妇,8名经验有限的受训者经标准化培训后在腰麻后与胎儿娩出后行FCU。腰麻后95.3%、胎儿娩出后89.1%的产妇可获得足以指导临床决策的图像,但A4CH视图质量受操作者影响。

要点

  • 经验有限的受训者经标准化培训后,在剖宫产产妇中多能获得可用于临床决策的FCU图像。
  • 腰麻后图像合格率高于胎儿娩出后,A4CH视图合格率最低且受操作者影响。
  • 左心室功能评估可行性高,右心室功能评估可行性相对较低。

核心结论

  • 剖宫产产妇中FCU可行,经验有限的受训者在几乎全部产妇中获得足以指导临床决策的图像。
  • A4CH视图的图像获取与质量可能受具体操作受训者影响。

研究设计与样本

  • 前瞻性队列研究,筛查95名产妇,最终64名健康足月单胎择期剖宫产产妇接受FCU检查。
  • 8名FCU经验有限的受训者,经8小时在线E-learning、1天面授课程及20至30次监督扫描培训并评估合格后实施检查。
  • 纳入标准为ASA≤3、≥37周妊娠、单胎、BMI<40 kg/m²、无先天性与获得性心脏病史。
  • 受训者在腰麻后术前及胎儿娩出后术中分别获取A4CH、PLAX、PSAX视图。
  • 图像由2名盲法导师按1至5分评分,≥3分定义为足以指导临床决策。

主要发现

  • 腰麻后61名(95.3%)、胎儿娩出后57名(89.1%)产妇可获得质量合格的图像。
  • 腰麻后9名(14.1%)、胎儿娩出后7名(10.9%)产妇可获得完美质量图像。
  • 腰麻后PLAX、PSAX、A4CH视图评分≥3者分别为53名(82.8%)、58名(90.6%)、40名(62.5%)。
  • 胎儿娩出后PLAX、PSAX、A4CH视图评分≥3者分别为50名(78.1%)、49名(76.6%)、29名(45.3%)。
  • 左心室功能在腰麻后40名中39名(97.5%)、胎儿娩出后40名中39名(97.5%)可评估;右心室功能分别为40名中31名(77.5%)与40名中23名(59%)。

临床怎么用

  • 经验有限的麻醉受训者经标准化培训后可在剖宫产围术期开展FCU,用于指导临床决策。
  • 需注意A4CH视图获取难度较大且受操作者影响,右心室功能评估可行性低于左心室。

局限性

  • 原文摘要未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Anesthesiology experts advocate for formal education in maternal critical care, including the use of focused cardiac ultrasound (FCU) in high-acuity obstetric units. While benefits and feasibility of FCU performed by experts have been well documented, little evidence exists on the feasibility of FCU acquired by examiners with limited experience. The primary aim of this study was to assess how often echocardiographic images of sufficient quality to guide clinical decision-making were attained by trainees with limited experience performing FCU in term parturients undergoing cesarean delivery (CD). METHODS: In this prospective cohort study, healthy term parturients (American Society of Anesthesiologists [ASA] ≤ 3, ≥37 weeks of gestation) with singleton pregnancy, body mass index (BMI) <40 kg/m 2 , and no history of congenital and acquired cardiac disease undergoing scheduled, elective CD were recruited by a trainee. After undergoing standardized training, including an 8-hour online E-learning module, a 1-day hands-on FCU course, and 20 to 30 supervised scans until the trainee was assessed competent in image acquisition, 8 trainees with limited FCU experience performed apical 4-chamber (A4CH), parasternal long-axis (PLAX), and short-axis (PSAX) view preoperatively after spinal anesthesia (SPA) and intraoperatively after neonatal delivery (ND). Obtained FCU images were graded 1 to 5 by 2 blinded instructors (1 = no image to 5 = perfect image obtainable; ≥3 defined as image quality sufficient for clinical decision-making). RESULTS: Following the screening of 95 women, 8 trainees with limited FCU experience each performed a median of 5 [3-8] FCUs in a total of 64 women. Images of sufficient quality were obtainable in 61 (95.3 %) and 57 (89.1 %) of women after SPA and ND, respectively. FCU images of perfect image quality were obtainable in 9 (14.1 %) and 7 (10.9 %) women preoperatively after SPA and intraoperatively after ND, respectively. A PLAX, PSAX, and A4CH view with grade ≥3 was obtained in 53 (82.8 %), 58 (90.6 %) and 40 (62.5 %) of women preoperatively after SPA and in 50 (78.1 %), 49 (76.6 %), and 29 (45.3 %) of women intraoperatively after ND. Left ventricular function could be assessed in 39 of 40 women (97.5 %) preoperatively after SPA and 39 of 40 (97.5%) intraoperatively after ND. Right ventricular function could be assessed in 31 of 40 (77.5 %) after SPA and in 23 of 40 (59%) after ND. We observed a difference in image grading between different trainees in the AP4CH-view ( P = .0001). No difference in image grading was found between preoperative and intraoperative FCUs. CONCLUSIONS: FCU is feasible in the parturient undergoing CD and images of sufficient quality for clinical decision-making were obtained by trainees with limited experience in almost all parturients. Image acquisition and quality in the A4CH view may be impacted by the individual trainee performing the FCU.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Ortner CM, Sheikh M, Athar MW, et al. Feasibility of Focused Cardiac Ultrasound Performed by Trainees During Cesarean Delivery. Anesth Analg. 2024. PMID: 38127663. doi:10.1213/ANE.0000000000006747

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。