清饮禁食推荐调整为1小时后不良呼吸事件发生率的多中心前瞻性观察研究
结果显示误吸发生率为0.11%,反流0.15%,呕吐0.37%,误吸未导致严重并发症或死亡;有效禁食时间<2小时与≥2小时组间误吸发生率无显著差异(P=0.678)。结论认为实施1小时清饮禁食国家推荐未增加误吸发生率。
要点
- 0-15岁患儿实施1小时清饮禁食后围术期误吸发生率为0.11%。
- 有效禁食时间<2小时与≥2小时组误吸发生率无显著差异(P=0.678)。
- 误吸未伴随严重并发症或死亡。
核心结论
- 实施1小时清饮禁食国家推荐与既往报告数据相比未增加误吸发生率。
主要发现
- 误吸25例(0.11%),胃反流34例(0.15%),呕吐85例(0.37%)。
- 误吸未伴随严重并发症或死亡。
- 清饮中位有效禁食时间为157分钟(IQR 104-314;范围2-2385)。
关键数值与推荐
- 主要结局为围术期(麻醉诱导至苏醒)误吸、胃反流和呕吐发生率。
- 清饮禁食推荐为1小时。
临床怎么用
- 在0-15岁择期手术患儿中可实施1小时清饮禁食推荐,未增加误吸风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Preoperative fasting reduces the risk of pulmonary aspiration during anaesthesia, and 2-h fasting for clear fluids has commonly been recommended. Based on recent evidence of shorter fasting times being safe, the Swiss Society of Paediatric Anaesthesia began recommending 1-h fasting for clear fluids in 2018. This prospective, observational, multi-institutional cohort study aimed to investigate the incidence of adverse respiratory events after implementing the new national recommendation. METHODS: Eleven Swiss anaesthesia institutions joined this cohort study and included patients aged 0-15 yr undergoing anaesthesia for elective procedures after implementation of the 1-h fasting instruction. The primary outcome was the perioperative (defined as the time from anaesthesia induction to emergence) incidence of pulmonary aspiration, gastric regurgitation, and vomiting. Data are presented as median (inter-quartile range; minimum-maximum) or count (percentage). RESULTS: From June 2019 to July 2021, 22 766 anaesthetics were recorded with pulmonary aspiration occurring in 25 (0.11%), gastric regurgitation in 34 (0.15%), and vomiting in 85 (0.37%) cases. No major morbidity or mortality was associated with pulmonary aspiration. Subgroup analysis by effective fasting times (<2 h [n=7306] vs ≥2 h [n=14 660]) showed no significant difference for pulmonary aspiration between these two groups (9 [0.12%] vs 16 [0.11%], P=0.678). Median effective fasting time for clear fluids was 157 [104-314; 2-2385] min. CONCLUSIONS: Implementing a national recommendation of 1-h clear fluid fasting was not associated with a higher incidence of pulmonary aspiration compared with previously reported data.
引用
- Schmitz A, Kuhn F, Hofmann J, et al. Incidence of adverse respiratory events after adjustment of clear fluid fasting recommendations to 1 h: a prospective, observational, multi-institutional cohort study. Br J Anaesth. 2023. PMID: 37953199. doi:10.1016/j.bja.2023.10.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。