硬脊膜穿刺硬膜外与常规硬膜外分娩镇痛启动:偏币序贯分配法测定90%患者有效布比卡因剂量
该随机偏币序贯分配试验纳入100例足月单胎、宫口≤5 cm的产妇,比较硬脊膜穿刺硬膜外(DPE)与常规硬膜外(EPL)技术启动分娩镇痛的布比卡因ED90。结果显示DPE的ED90为29.30 mg(90%CI 28.55-31.56),EPL为45.25 mg(90%CI 42.80-52.03),DPE所需布比卡因剂量更低。
要点
- DPE技术启动分娩镇痛的布比卡因ED90低于EPL技术
- DPE的ED90为29.30 mg,EPL的ED90为45.25 mg
- 研究采用偏币序贯分配法,以30分钟NRS<3定义成功
核心结论
- DPE技术达到有效初始分娩镇痛所需的布比卡因ED90低于EPL技术。
研究设计与样本
- 随机偏币序贯分配试验,纳入100例足月单胎、宫口≤5 cm、无重大合并症的混合产次产妇。
- 最终95例纳入分析,随机接受DPE或EPL技术,由经验丰富的麻醉科医生操作。
- 布比卡因剂量由前一例反应决定,成功定义为30分钟时NRS<3,ED90用中心等渗回归估计。
主要发现
- DPE技术布比卡因ED90为29.30 mg(90%CI 28.55-31.56)。
- EPL技术布比卡因ED90为45.25 mg(90%CI 42.80-52.03)。
关键数值与推荐
- 成功标准为30分钟时NRS<3。
- 布比卡因用0.9%生理盐水稀释至总容积20 mL,经硬膜外导管给予。
临床怎么用
- DPE技术可考虑用于降低启动分娩镇痛所需的布比卡因剂量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The dural puncture epidural (DPE) technique has a faster onset, better sacral spread, and improved bilateral coverage when compared to the conventional epidural (EPL) technique. Whether these qualities translate into a lower bupivacaine dose to provide initial analgesia is unknown. We sought to determine the effective dose of bupivacaine to achieve initial (first 30 minutes) labor analgesia in 90% of patients (ED90) with the DPE and EPL techniques, using a biased-coin, sequential allocation method. METHODS: A total of 100 women of mixed parity with term, singleton gestation at ≤5 cm dilation with no major comorbidities were randomized to receive a DPE or an EPL technique. An experienced anesthesiologist performed these techniques and administered an allocated dose of plain bupivacaine diluted with isotonic sterile 0.9% saline to a total volume of 20 mL via the EPL catheter. Bupivacaine doses for each subject were determined by the response of the previous subject, using a biased-coin sequential allocation method, with success defined by a numeric rating scale (NRS) < 3 at 30 minutes. Outcome assessments were performed by an investigator blinded to the technique and bupivacaine dose. Sensory and motor blockade and maternal or fetal side effects were recorded every 5 minutes for the first 30 minutes. The ED90 of bupivacaine with each technique was estimated using centered isotonic regression. RESULTS: A total of 95 women were included in the final analysis. The ED90 of bupivacaine was estimated at 29.30 mg (90% confidence interval [CI], 28.55-31.56) with a DPE technique and 45.25 mg (90% CI, 42.80-52.03) with an EPL technique. CONCLUSIONS: Using a biased-coin, sequential allocation method, the DPE technique requires less bupivacaine to achieve effective initial analgesia (ED90) when compared to the EPL technique.
引用
- Maeda A, Villela-Franyutti D, Lumbreras-Marquez MI, et al. Labor Analgesia Initiation With Dural Puncture Epidural Versus Conventional Epidural Techniques: A Randomized Biased-Coin Sequential Allocation Trial to Determine the Effective Dose for 90% of Patients of Bupivacaine. Anesth Analg. 2023. PMID: 37824436. doi:10.1213/ANE.0000000000006691
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。