文献速递心胸血管麻醉

体外循环期间动脉高氧血症与术后肺功能恶化无关:回顾性队列研究

Arterial Hyperoxemia During Cardiopulmonary Bypass Was Not Associated With Worse Postoperative Pulmonary Function: A Retrospective Cohort Study.
PubMed 文献 · Anesth Analg · 2023-09-21

次要分析未发现PaO2与CPB后6小时峰值乳酸、平均乳酸或KDIGO标准急性肾损伤显著相关。

要点

  • 体外循环期间PaO2时间加权平均值与术后P/F比值呈弱正相关,未见肺功能恶化。
  • PaO2与CPB后6小时乳酸水平及KDIGO标准急性肾损伤无显著关联。

核心结论

  • 体外循环期间PaO2与术后肺功能无临床显著关联。
  • PaO2与乳酸水平、术后肾功能或其他探索性结局亦无关联。

研究设计与样本

  • 9141例患者符合纳入和排除标准,8429例(92.2%)基线变量完整并纳入分析;平均年龄64岁(SD=13),男性占68%(n=6208)。
  • 主要结局为术后6小时或拔管前PaO2/FiO2比值;采用线性或逻辑回归模型调整可用基线混杂因素,评估体外循环在线样本监测PaO2与结局的关联。

临床怎么用

  • 本研究未发现体外循环期间动脉高氧血症与术后肺功能恶化相关的证据,提示临床无需仅基于术后肺功能担忧而刻意限制PaO2。
  • PaO2与乳酸、急性肾损伤等器官灌注指标无显著关联,支持在体外循环期间维持常规氧合管理。

局限性

  • 本研究为回顾性队列设计,仅能提示关联而非因果关系。
  • 研究对象限于单中心择期心脏手术患者,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Arterial hyperoxemia may cause end-organ damage secondary to the increased formation of free oxygen radicals. The clinical evidence on postoperative lung toxicity from arterial hyperoxemia during cardiopulmonary bypass (CPB) is scarce, and the effect of arterial partial pressure of oxygen (Pa o2 ) during cardiac surgery on lung injury has been underinvestigated. Thus, we aimed to examine the relationship between Pa o2 during CPB and postoperative lung injury. Secondarily, we examined the relationship between Pa o2 and global (lactate), and regional tissue malperfusion (acute kidney injury). We further explored the association with regional tissue malperfusion by examining markers of cardiac (troponin) and liver injury (bilirubin). METHODS: This was a retrospective cohort study including patients who underwent elective cardiac surgeries (coronary artery bypass, valve, aortic, or combined) requiring CPB between April 2015 and December 2021 at a large quaternary medical center. The primary outcome was postoperative lung function defined as the ratio of Pa o2 to fractional inspired oxygen concentration (F io2 ); P/F ratio 6 hours following surgery or before extubation. The association between CPB in-line sample monitor Pa o2 and primary, secondary, and exploratory outcomes was evaluated using linear or logistic regression models adjusting for available baseline confounders. RESULTS: A total of 9141 patients met inclusion and exclusion criteria, and 8429 (92.2%) patients had complete baseline variables available and were included in the analysis. The mean age of the sample was 64 (SD = 13), and 68% were men (n = 6208). The time-weighted average (TWA) of in-line sample monitor Pa o2 during CPB was weakly positively associated with the postoperative P/F ratio. With a 100-unit increase in Pa o2 , the estimated increase in postoperative P/F ratio was 4.61 (95% CI, 0.71-8.50; P = .02). Our secondary analysis showed no significant association between Pa o2 with peak lactate 6 hours post CPB (geometric mean ratio [GMR], 1.01; 98.3% CI, 0.98-1.03; P = .55), average lactate 6 hours post CPB (GMR, 1.00; 98.3% CI, 0.97-1.03; P = .93), or acute kidney injury by Kidney Disease Improving Global Outcomes (KDIGO) criteria (odds ratio, 0.91; 98.3% CI, 0.75-1.10; P = .23). CONCLUSIONS: Our investigation found no clinically significant association between Pa o2 during CPB and postoperative lung function. Similarly, there was no association between Pa o2 during CPB and lactate levels, postoperative renal function, or other exploratory outcomes.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Kelava M, Milam AJ, Mi J, et al. Arterial Hyperoxemia During Cardiopulmonary Bypass Was Not Associated With Worse Postoperative Pulmonary Function: A Retrospective Cohort Study. Anesth Analg. 2023. PMID: 37733624. doi:10.1213/ANE.0000000000006627

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。