文献速递区域麻醉与超声疼痛医学

传统与隧道化收肌管阻滞导管迁移率比较:随机对照试验

Comparison of migration rates between traditional and tunneled adductor canal block catheters: a randomized controlled trial.
PubMed 文献 · Reg Anesth Pain Med · 2024-06-03

结果显示ISAFE组术后24小时导管移出收肌管的发生率显著低于对照组(18.6% vs 44.9%,p=0.01),且术后前两日静息疼痛评分更低。结论认为连续收肌管阻滞的镇痛效果取决于导管尖端是否位于收肌管内。

要点

  • ISAFE入路可降低收肌管导管术后24小时移出率。
  • ISAFE组术后前两日静息疼痛评分更低。
  • 导管尖端位置是连续收肌管阻滞镇痛效果的关键。

核心结论

  • ISAFE入路放置收肌管导管的术后24小时移出率显著低于传统入路。
  • 连续收肌管阻滞对膝关节置换的镇痛获益取决于导管尖端是否位于收肌管内。

研究设计与样本

  • 主要结局为术后24小时超声评估收肌管导管移出收肌管的发生率。

主要发现

  • ISAFE组术后24小时导管移出率为18.6%,对照组为44.9%(p=0.01)。
  • ISAFE组术后前两日静息疼痛评分低于对照组。

关键数值与推荐

  • 主要结局:术后24小时超声评估导管移出收肌管的发生率,ISAFE组18.6% vs 对照组44.9%,p=0.01。
  • 次要结局包括术后48小时内疼痛评分、阿片类药物消耗及连续收肌管阻滞相关并发症。

临床怎么用

  • 采用ISAFE入路放置收肌管导管可能减少导管移出,有助于维持连续阻滞的镇痛效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Total knee arthroplasty is associated with significant postoperative pain. Continuous adductor canal blocks via an inserted adductor canal catheter are effective analgesia interventions with the advantage of decreasing quadriceps weakness and the potential of extending the analgesic effect. The classical adductor canal catheter insertion technique may have a high likelihood of catheter dislodgement out of the canal. The interfascial plane between the sartorius muscle and femoral artery (ISAFE) approach has the potential of decreasing the adductor canal catheter migration. The purpose of this study was to evaluate the incidence of catheter dislodgment to outside the adductor canal, for ISAFE and classical approaches. We hypothesized that ISAFE approach would result in a lower dislodgment rate. METHODS: Ninety-seven patients for unilateral total knee arthroplasty were included and randomized to either ISAFE intervention group or conventional group. The primary outcome was the incidence of adductor canal catheter dislodged to outside the adductor canal, on ultrasound evaluation, 24 hours after the surgery. Secondary outcomes were pain scores, opioid consumption and continuous adductor canal block related complications for the first 48 hours after surgery. RESULTS: The catheters placed using ISAFE approach had a lower rate of dislodgement in comparison to the control group (18.6% vs 44.9%, respectively, p=0.01), at 24 hours after surgery; and lower pain scores for rest, on the first two postoperative days. CONCLUSIONS: ISAFE group had a significantly lower rate of dislodgement at 24 hours. The continuous adductor canal block analgesic benefit for knee arthroplasty depends on the position of the tip of the catheter inside the adductor canal.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Gleicher Y, Dos Santos Fernandes H, Peacock S, et al. Comparison of migration rates between traditional and tunneled adductor canal block catheters: a randomized controlled trial. Reg Anesth Pain Med. 2024. PMID: 37704437. doi:10.1136/rapm-2023-104654

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。