简单步骤改善产科气道管理安全:一项质量改进项目
该前瞻性质量改进项目在大型三级产科单位纳入401例>20周妊娠或产后48小时内全麻下产科手术患者,分三个6个月阶段评估干预效果。视频喉镜使用率从2019年60%升至2022年94%,气管插管全部成功,总首次通过率94%。插管核查表、低流量鼻氧和斜坡体位使用率亦提升。
要点
- 视频喉镜使用率由60%升至94%,插管全部成功,首次通过率94%。
- 低流量鼻氧使用率由48%升至90%,斜坡体位由95%升至97%。
- 插管核查表使用率由63%升至92%,多学科培训支持了这些简单安全措施。
核心结论
- 将视频喉镜、斜坡体位和低流量鼻氧等简单安全措施引入常规实践获得成功,插管核查表和多学科团队培训起到支持作用。
研究设计与样本
- 在大型三级转诊产科单位纳入401例>20周妊娠或产后48小时内全麻下产科手术患者。
主要发现
- 共记录334例气管插管(占83.3%)。
- 视频喉镜使用率从2019年60%升至2021年88%,再至2022年94%。
- 气管插管全部成功,总体首次通过率94%,仅0.9%需要三次尝试。
- 低流量鼻氧使用率从2019年48%升至2022年90%;斜坡体位从2021年95%升至2022年97%;核查表使用率从2021年63%升至2022年92%。
关键数值与推荐
- 产科麻醉医师协会和困难气道协会指南指出:所有产科全麻应即刻可用视频喉镜。
临床怎么用
- 在产科全麻中常规配备并使用视频喉镜,结合插管核查表、低流量鼻氧和斜坡体位。
- 通过多学科团队培训推动上述简单安全措施落地。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Guidelines from the Obstetric Anaesthetists' Association and Difficult Airway Society state that 'a videolaryngoscope should be immediately available for all obstetric general anaesthetics'. OBJECTIVE: To report the incidence of videolaryngoscopy use, and other airway management safety interventions, in an obstetric population before and after various quality improvement interventions. DESIGN: Prospective data collection was undertaken over 18 months, divided into three separate 6-month periods: June to November 2019; March to August 2021; January to June 2022. These periods relate to evaluation of specific quality improvement interventions. SETTING: The project was carried out in a large tertiary referral obstetric unit. PATIENTS: We identified 401 pregnant women (> 20 weeks' gestation) and postnatal women (up to 48 h post delivery) undergoing an obstetric surgical procedure under general anaesthesia. INTERVENTIONS: To standardise practice, an intubation checklist was introduced in December 2020 and multidisciplinary staff training in August 2021. MAIN OUTCOME MEASURES: Primary outcome measures were use of a Macintosh-style videolaryngoscope and tracheal intubation success. Secondary outcome measures were use of an intubation checklist; low flow nasal oxygen; and ramped patient positioning. RESULTS: Data from 334 tracheal intubations (83.3% of cases) were recorded. Videolaryngoscope use increased from 60% in 2019, to 88% in 2021, to 94% in 2022. Tracheal intubation was successful in all patients, with 94% first pass success overall and only 0.9% requiring three attempts. Use of secondary outcome measures also increased: low flow nasal oxygen from 48% in 2019 to 90% in 2022; ramped positioning from 95% in 2021 to 97% in 2022; and checklist use from 63% in 2021 to 92% in 2022. CONCLUSIONS: We describe the successful adoption of simple safety measures introduced into routine practice. These comprised videolaryngoscopy, ramped positioning and low flow nasal oxygen. Their introduction was supported by the implementation of an intubation checklist and multidisciplinary team training.
引用
- Critchley JD, Ferguson C, Kidd E, et al. Simple steps towards improving safety in obstetric airway management: A quality improvement project. Eur J Anaesthesiol. 2023. PMID: 37646501. doi:10.1097/EJA.0000000000001897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。