颈椎固定患者气管插管:视频喉镜与可弯曲纤维支气管镜的随机对照试验
本研究为随机对照试验,在颈椎领固定模拟困难气道的择期颈椎手术患者中比较视频喉镜(非通道Macintosh镜片,n=166)与可弯曲纤维支气管镜(n=164)的气管插管效果。主要结局首次插管成功率视频喉镜组98.8%高于纤维支气管镜组90.9%(p=0.003),且视频喉镜组插管时间更短、需额外气道操作更少,两组插管相关气道并发症发生率和严重程度无差异。
要点
- 颈椎领固定患者中,视频喉镜首次插管成功率高于可弯曲纤维支气管镜。
- 视频喉镜插管时间更短,需额外气道操作更少。
- 两组插管相关气道并发症发生率和严重程度无差异。
核心结论
- 在颈椎领固定患者中,使用非通道Macintosh镜片的视频喉镜行气管插管优于可弯曲纤维支气管镜。
研究设计与样本
- 随机对照试验,比较视频喉镜(n=166)与可弯曲纤维支气管镜(n=164)在颈椎领固定的择期颈椎手术患者中的气管插管效果。
主要发现
- 首次插管成功率视频喉镜组164/166(98.8%)高于纤维支气管镜组149/164(90.9%),p=0.003。
- 所有患者均在三次尝试内插管成功。
- 插管时间中位数(IQR[范围])视频喉镜组为50.0(41.0-72.0[25.0-170.0])秒,短于纤维支气管镜组的81.0(65.0-107.0[24.0-178.0])秒,p<0.001。
- 需额外气道操作视频喉镜组30/166(18.1%)少于纤维支气管镜组91/164(55.5%),p<0.001。
- 两组插管相关气道并发症发生率和严重程度无差异。
关键数值与推荐
- 首次插管成功率:视频喉镜组98.8% vs 纤维支气管镜组90.9%,p=0.003。
- 插管时间中位数:视频喉镜组50.0秒 vs 纤维支气管镜组81.0秒,p<0.001。
- 额外气道操作比例:视频喉镜组18.1% vs 纤维支气管镜组55.5%,p<0.001。
临床怎么用
- 对颈椎领固定患者行气管插管时,可优先选择非通道Macintosh镜片的视频喉镜以提高首次插管成功率并缩短插管时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
In patients with cervical spine immobilisation, tracheal intubation devices other than a direct laryngoscope are frequently used to facilitate tracheal intubation and avoid related complications. In this randomised controlled trial, we compared videolaryngoscopic and fibrescopic tracheal intubation in patients with a cervical collar. Tracheal intubation was performed using either a videolaryngoscope with a non-channelled Macintosh blade (n = 166) or a flexible fibrescope (n = 164) in patients having elective cervical spine surgery whose neck was immobilised with a cervical collar to simulate a difficult airway. The primary outcome was the first attempt success rate of tracheal intubation. Secondary outcomes were the overall success rate of tracheal intubation; time to tracheal intubation; use of additional airway manoeuvres; and incidence and severity of tracheal intubation-related airway complications. First attempt success rate was higher in the videolaryngoscope group than in the fibrescope group (164/166 (98.8%) vs. 149/164 (90.9%), p = 0.003). Tracheal intubation was successful within three attempts in all patients. Median (IQR [range]) time to tracheal intubation was shorter (50.0 (41.0-72.0 [25.0-170.0]) s vs. 81.0 (65.0-107.0 [24.0-178.0]) s, p < 0.001) and additional airway manoeuvres were less frequent (30/166 (18.1%) vs. 91/164 (55.5%), p < 0.001) in the videolaryngoscope group compared with the fibrescope group. The incidence and severity of intubation-related airway complications were not different between the two groups. When performing tracheal intubation in patients with a cervical collar, videolaryngoscopy with a non-channelled Macintosh blade was superior to flexible fibrescopy.
引用
- Choi S, Yoo HK, Shin KW, et al. Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial. Anaesthesia. 2023. PMID: 37145935. doi:10.1111/anae.16035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。