文献速递心胸血管麻醉区域麻醉与超声

星状神经节阻滞导管治疗难治性电风暴:回顾性队列与诊疗路径

Stellate ganglion block catheters for refractory electrical storm: a retrospective cohort and care pathway.
PubMed 文献 · Reg Anesth Pain Med · 2023-02-01

该回顾性队列研究纳入2020年1月至2022年4月心血管重症监护室中因电风暴接受星状神经节阻滞(SGB)的患者,11例符合标准。左侧SGB后90%(n=10)患者电风暴持续停止24小时,90%(n=10)在SGB后6小时内无需要干预的室性心律失常发作。结论认为SGB可中断或治疗电风暴,SGB导管可延长心律失常停止时间并降低复发风险。

要点

  • 左侧SGB后90%患者电风暴停止持续24小时。
  • 90%患者SGB后6小时内无需要干预的室性心律失常。
  • SGB导管可延长疗效,避免重复阻滞。

核心结论

  • SGB可中断或治疗电风暴,SGB导管允许长时间心律失常停止而无需重复阻滞,并降低室性心律失常复发风险。

研究设计与样本

  • 回顾性队列研究,纳入2020年1月至2022年4月心血管重症监护室中因电风暴接受SGB的患者,共识别27例,11例符合纳入标准。

主要发现

  • 左侧SGB后90%(n=10)患者实现电风暴持续停止24小时。
  • 90%(n=10)患者在SGB后6小时内无记录的需干预的室性心律失常发作。

临床怎么用

  • 对于难治性电风暴,可考虑使用SGB导管以延长心律失常停止时间并减少重复阻滞。

局限性

  • 回顾性研究,样本量小(11例符合标准),数据关于SGB导管治疗电风暴稀缺。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Electrical storm can be challenging to treat, requiring a multidisciplinary team to coordinate medical management and invasive procedures. As the stellate ganglion provides efferent sympathetic outflow to the myocardium, stellate ganglion blocks (SGB) can be used to combat ventricular arrhythmias that arise from sympathetic overactivity. Data are scarce regarding SGB catheters as a treatment for electrical storm. We reviewed our use of SGB catheters for refractory electrical storm using our pathway collaboratively developed by critical care, cardiology, and regional anesthesia teams. METHODS: We conducted a retrospective cohort study of patients who underwent an SGB for electrical storm between January 2020 and April 2022 in our cardiovascular intensive care unit. The primary outcome was the sustained cessation of electrical storm for 24 hours. RESULTS: Upon chart review, 27 patients were identified and 11 met inclusion criteria. Cessation of electrical storm for 24 hours was achieved in 90% (n=10) of patients after left SGB. Similarly, 90% (n=10) had no documented episodes of ventricular arrhythmias requiring intervention within 6 hours after SGB. CONCLUSIONS: SGBs can interrupt or treat electrical storm. SGB catheters allow for prolonged arrhythmia cessation without repeated blocks and decrease the risk of repeat episodes of ventricular arrhythmias.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Patel RA, Condrey JM, George RM, et al. Stellate ganglion block catheters for refractory electrical storm: a retrospective cohort and care pathway. Reg Anesth Pain Med. 2023. PMID: 36725213. doi:10.1136/rapm-2022-104172

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。