彩色多普勒超声在分娩硬膜外置管定位中的应用
本研究为前瞻性观察队列,纳入40例接受硬膜外分娩镇痛的阴道分娩患者,用彩色多普勒超声在注射生理盐水时观察硬膜外腔血流信号。结果所有40例均可见血流信号,37/40(93%)在注射1mL生理盐水时可见,其余3/40(7%)需空气/盐水混合液;提示该技术可行且快速,可用于确认导管位置及处理镇痛不佳。
要点
- 彩色多普勒超声注射生理盐水可观察硬膜外腔血流信号,40例均成功。
- 37/40(93%)在注射1mL生理盐水时可见血流,3/40(7%)需空气/盐水混合液。
- 血流信号仅见于置管间隙或上方一个间隙,提示导管多留在置管间隙。
核心结论
- 彩色多普勒超声是确定产科人群硬膜外腔血流的可行且快速的方法,可用于确认导管位置及处理镇痛不佳。
研究设计与样本
- 前瞻性观察队列研究,纳入40例在硬膜外镇痛下经阴道分娩的患者,使用5-2 mHz凸阵探头在左右旁正中纵斜切面观察置管间隙及上下各一间隙。
主要发现
- 所有40例患者均可见硬膜外腔血流信号。
- 注射1mL生理盐水时37/40(93%)可见血流,其余3/40(7%)用空气/盐水混合液可见。
- 注射生理盐水时血流仅见于置管间隙26/37(70%),置管间隙及上方一个间隙10/37(27%),仅上方一个间隙1/37(3%)。
- 19/37(51%)患者血流仅见于左侧或右侧旁正中视图,尽管所有患者感觉阻滞对称。
关键数值与推荐
- 注射1mL生理盐水后使用彩色多普勒观察硬膜外腔血流;若所有间隙未见血流,则在置管水平重复评估并改用1mL空气/盐水混合液。
临床怎么用
- 可用于硬膜外置管后确认导管位置,以及处理镇痛效果不佳时的故障排查。
局限性
- 研究为便利样本40例,样本量小;未报告敏感性、特异性等诊断准确性指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ultrasound is commonly used to facilitate epidural catheter placement. However, data are lacking regarding its potential to confirm its position in the epidural space. Our aim was to visualize flow in the epidural space of patients receiving epidural analgesia for labor using color flow Doppler ultrasound. METHODS: We conducted a prospective observational cohort study that included patients who had delivered vaginally under epidural analgesia. We used a 5-2 mHz curvilinear probe in a left and right paramedian longitudinal oblique view to visualize the anterior and posterior complex at the interspace of epidural catheter insertion, one and two interspaces above and below. At each window, the color flow Doppler function was used to visualize flow within the epidural space on injection of normal saline (1 mL). If no flow was visualized at any interspace, one assessment at the level of insertion was repeated with a 1 mL air/saline mixture. We studied a convenience sample size of 40 patients. RESULTS: We visualized flow in the epidural space in all 40 patients. Flow was visualized on injection of 1 mL of saline in 37/40 patients (93%). In the remaining 3/40 patients (7%), flow was visualized with an air/saline mixture. Flow on injection of saline was visualized only at the interspace of insertion in 26/37 patients (70%), at the interspace of insertion and one interspace above in 10/37 (27%), or only at one interspace above in 1/37 (3%). Flow was visualized only on the left or on the right paramedian view in 19/37 patients (51%), despite a symmetrical sensory block in all patients. CONCLUSION: Color flow Doppler ultrasound is a feasible and fast way to determine flow in the epidural space in the obstetric population. Its potential clinical uses are confirmation of the epidural catheter position after placement, as well as troubleshooting of unsatisfactory epidural analgesia. Interestingly, our results suggest that epidural catheters predominantly remain at the interspace of insertion. TRIAL REGISTRATION NUMBER: NCT05126745.
引用
- van den Bosch OFC, Gleicher Y, Arzola C, et al. Color flow Doppler in spinal ultrasound: a novel technique for assessment of catheter position in labor epidurals. Reg Anesth Pain Med. 2022. PMID: 36215115. doi:10.1136/rapm-2022-103948