辅助人工智能对区域麻醉超声扫描影响的评估
该探索性研究让21名区域麻醉超声非专家在标准化教学后完成六种外周神经阻滞扫描,一半使用辅助AI设备。专家评估显示,使用AI设备时正确获得阻滞切面的比例为90.3%(56/62),高于未使用时的75.1%(47/62,P=0.031);正确识别超声解剖结构的比例为88.8%(188/212),高于未使用时的77.4%(161/208,P=0.002)。参与者信心、专家整体评分和扫描时间无显著差异。
要点
- 辅助AI设备可提高非专家获取正确阻滞切面的比例。
- 辅助AI设备可提高非专家识别超声解剖结构的正确率。
- 参与者信心、专家整体评分及扫描时间未见显著差异。
核心结论
- 使用辅助AI设备与超声图像获取和解读改善相关,可能扩展非专家开展区域麻醉超声扫描的能力。
研究设计与样本
- 探索性研究,21名区域麻醉超声非专家在标准化教学后完成六种外周神经阻滞扫描,半数组扫描使用AI辅助、半数未使用。
- 专家评估126次超声扫描,比较正确阻滞切面获取、超声解剖结构正确识别、参与者信心、专家整体评分和扫描时间。
主要发现
- 使用AI设备时正确获取阻滞切面的比例为56/62(90.3%),未使用时为47/62(75.1%),P=0.031,缺失2个数据点。
- 使用AI设备时正确识别超声解剖结构的比例为188/212(88.8%),未使用时为161/208(77.4%),P=0.002。
- 参与者信心、专家整体表现评分和扫描时间总体上无显著差异。
临床怎么用
- 辅助AI设备可用于支持非专家在区域麻醉超声扫描中获取正确切面和识别解剖结构。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ultrasound-guided regional anaesthesia relies on the visualisation of key landmark, target, and safety structures on ultrasound. However, this can be challenging, particularly for inexperienced practitioners. Artificial intelligence (AI) is increasingly being applied to medical image interpretation, including ultrasound. In this exploratory study, we evaluated ultrasound scanning performance by non-experts in ultrasound-guided regional anaesthesia, with and without the use of an assistive AI device. METHODS: Twenty-one anaesthetists, all non-experts in ultrasound-guided regional anaesthesia, underwent a standardised teaching session in ultrasound scanning for six peripheral nerve blocks. All then performed a scan for each block; half of the scans were performed with AI assistance and half without. Experts assessed acquisition of the correct block view and correct identification of sono-anatomical structures on each view. Participants reported scan confidence, experts provided a global rating score of scan performance, and scans were timed. RESULTS: Experts assessed 126 ultrasound scans. Participants acquired the correct block view in 56/62 (90.3%) scans with the device compared with 47/62 (75.1%) without (P=0.031, two data points lost). Correct identification of sono-anatomical structures on the view was 188/212 (88.8%) with the device compared with 161/208 (77.4%) without (P=0.002). There was no significant overall difference in participant confidence, expert global performance score, or scan time. CONCLUSIONS: Use of an assistive AI device was associated with improved ultrasound image acquisition and interpretation. Such technology holds potential to augment performance of ultrasound scanning for regional anaesthesia by non-experts, potentially expanding patient access to these techniques. CLINICAL TRIAL REGISTRATION: NCT05156099.
引用
- Bowness JS, Macfarlane AJR, Burckett-St Laurent D, et al. Evaluation of the impact of assistive artificial intelligence on ultrasound scanning for regional anaesthesia. Br J Anaesth. 2022. PMID: 36088136. doi:10.1016/j.bja.2022.07.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。