文献速递区域麻醉与超声疼痛医学

增强现实引导椎管内穿刺的体模研究

Usage of augmented reality for interventional neuraxial procedures: A phantom-based study.
PubMed 文献 · Eur J Anaesthesiol · 2022-09-19

该随机体模研究评估增强现实引导椎管内穿刺的技术可行性,主要结局为首次穿刺成功率。四名操作者共完成20次尝试,增强现实组成功率82.5%,传统组40%(P=0.0002,OR=7.07);增强现实组欧氏距离、侧向偏差更小,操作时间更短。

要点

  • 增强现实引导可提高体模上椎管内穿刺首次成功率。
  • 增强现实引导的穿刺精度更高、操作时间更短。
  • 结论需进一步技术开发后在解剖困难病例中验证。

核心结论

  • 在实验性体模模型中,增强现实引导显著提高了硬膜外穿刺的准确性和成功率。

研究设计与样本

  • 随机体模研究,使用胸腰段脊柱体模,由4名操作者(2名麻醉医师、1名神经放射医师、1名立体定向神经外科医师)共完成20次尝试。

主要发现

  • 增强现实组首次穿刺成功率为82.5%,传统组为40%(P=0.0002,成功OR=7.07)。
  • 增强现实组欧氏距离为6.1 mm,传统组为12 mm(P<0.0001)。
  • 增强现实组侧向偏差为3.7 mm,传统组为9.2 mm(P<0.0001)。
  • 增强现实组穿刺时间为52.5 s,传统组为67.5 s(P=0.0015)。

临床怎么用

  • 在体模条件下,增强现实引导可辅助提高椎管内穿刺首次成功率和精度。
  • 该技术可能有助于解剖困难的椎管内操作,但需进一步技术开发与临床验证。

局限性

  • 研究为体模实验,非临床患者,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Neuraxial access is necessary for an array of procedures in anaesthesia, interventional pain medicine and neurosurgery. The commonly used anatomical landmark technique is challenging and requires practical experience. OBJECTIVE: We aimed to evaluate the technical feasibility of an augmented reality-guided approach for neuraxial access and tested the hypothesis that its use would improve success as the primary outcome. As secondary outcomes, we measured accuracy and the procedural duration compared with the classical landmark approach. DESIGN: A randomised phantom-based study. SETTING: The three-dimensional image of a thoracolumbar phantom spine model with the surrounding soft tissue was created with a neurosurgical planning workstation and ideal trajectories to the epidural space on the levels T10-L1 were planned using a paramedian approach. Both the three-dimensional holographic image of the spine and the trajectories were transferred to an augmented reality-headset. Four probands (two anaesthesiologists, one neuroradiologist and one stereotactic neurosurgeon) performed 20 attempts, 10 each of either conventional landmark or augmented reality-guided epidural punctures, where anatomical level, side and sequence of modality were all randomised. OUTCOME MEASURES: Accuracy was assessed by measuring Euclidean distance and lateral deviation from the predefined target point. Success of epidural puncture on the first attempt was compared between the conventional and the augmented reality-guided approaches. RESULTS: Success was achieved in 82.5% of the attempts using augmented reality technique, compared with 40% with the conventional approach [ P = 0.0002, odds ratio (OR) for success: 7.07]. Euclidean distance (6.1 vs. 12 mm, P < 0.0001) and lateral deviation (3.7 vs. 9.2 mm, P < 0.0001) were significantly smaller using augmented reality. Augmented reality-guided puncture was significantly faster than with the conventional landmark approach (52.5 vs. 67.5 s, P = 0.0015). CONCLUSION: Augmented reality guidance significantly improved the accuracy and success in an experimental phantom model of epidural puncture. With further technical development, augmented reality guidance might prove helpful in anatomically challenging neuraxial procedures.

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Reinacher PC, Cimniak A, Demerath T, et al. Usage of augmented reality for interventional neuraxial procedures: A phantom-based study. Eur J Anaesthesiol. 2022. PMID: 36121289. doi:10.1097/EJA.0000000000001755

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。