直接喉镜与视频喉镜对甲状腺手术喉返神经监测信号质量的影响:一项随机平行组试验
这项前瞻性随机试验纳入260例甲状腺手术成人患者,比较C-MAC视频喉镜与直接喉镜对气管插管后喉返神经监测信号质量的影响。主要结局为插管成功后肌电图振幅不足(<500 μV)的发生率,直接喉镜组为27%,显著高于C-MAC组的9%(p<0.001)。视频喉镜可优化表面电极定位,改善术中神经监测初始信号质量。
要点
- 视频喉镜组信号不足发生率9%,显著低于直接喉镜组的27%。
- 视频喉镜首次插管成功率96%,高于直接喉镜的66%。
- 视频喉镜组Cormack-Lehane分级≥3级为0%,直接喉镜组为12%。
核心结论
- 视频喉镜可改善甲状腺手术中喉返神经监测的初始信号质量,提供更优的表面电极定位。
研究设计与样本
- 前瞻性随机平行组试验,纳入260例甲状腺手术成人患者,每组130例,分别使用C-MAC视频喉镜(Macintosh型镜片)或直接喉镜。
主要发现
- 插管成功后肌电图振幅不足(<500 μV)发生率:直接喉镜组35/130(27%),C-MAC组12/130(9%),p<0.001。
- 首次插管成功率:直接喉镜组86/130(66%),C-MAC组125/130(96%),p<0.0001。
- Cormack-Lehane分级≥3级发生率:直接喉镜组16/130(12%),C-MAC组0/130(0%),p<0.0001。
临床怎么用
- 在甲状腺手术需进行喉返神经监测时,可优先选择视频喉镜以优化气管导管表面电极位置,提高监测信号质量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
In thyroid surgery, intra-operative neuromonitoring signals of the recurrent laryngeal nerve can be detected by surface electrodes on a tracheal tube positioned at the vocal fold level. The incidence of difficult tracheal intubation in patients undergoing thyroidectomy for nodular goitre ranges from 5.3% to 20.5%. The aim of this study was to compare videolaryngoscopy with conventional direct laryngoscopy as methods for proper placement of the surface electrode to prevent insufficient intra-operative nerve signal quality. In this prospective randomised trial, adult patients requiring tracheal intubation during thyroid surgery were randomly allocated to two groups of C-MAC® (Macintosh style blade) videolaryngoscope or direct laryngoscopy using the Macintosh laryngoscope. Primary outcome was the incidence of insufficient signal electromyogram amplitude level (< 500 μV) after successful tracheal intubation. A total of 260 (130 per group) participants were analysed. An insufficient signal was more frequent with direct laryngoscopy (35/130, 27%), compared with C-MAC (12/130, 9%, p < 0.001). First-pass tracheal intubation success rate was lower with direct laryngoscopy (86/130 (66%)) compared with the C-MAC (125/130 (96%)) (p < 0.0001). Cormack and Lehane grade ≥ 3 was observed more frequently with direct laryngoscopy (16/130 (12%)), compared with the C-MAC (0/130, (0%)) (p < 0.0001). The results suggest that videolaryngoscopy has an impact on the quality of the initial intra-operative neuromonitoring signal in patients undergoing thyroid surgery, and this technique can provide optimised surface electrode positioning.
引用
- Kriege M, Hilt JA, Dette F, et al. Impact of direct laryngoscopy vs. videolaryngoscopy on signal quality of recurrent laryngeal nerve monitoring in thyroid surgery: a randomised parallel group trial. Anaesthesia. 2022. PMID: 36166515. doi:10.1111/anae.15865
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。