气溶胶防护与气道并发症:全国前瞻性多中心队列研究
该研究在96小时内纳入70家医院5905例全麻成年患者,评估气溶胶防护措施与围术期气道并发症的关系。使用过滤式面罩2级或3级呼吸器与气道并发症风险增加相关(OR 1.38,95%CI 1.04-1.83),主要与面罩通气困难和脉搏血氧饱和度下降相关;护目镜、电动空气净化呼吸器、长袖隔离衣、双层手套和视频喉镜未改变气道并发症风险。
要点
- 使用过滤式面罩2级或3级呼吸器增加气道并发症风险(OR 1.38,95%CI 1.04-1.83)。
- 该风险主要与面罩通气困难(OR 1.68)和血氧饱和度下降(OR 2.39)相关。
- 护目镜、电动空气净化呼吸器、长袖隔离衣、双层手套和视频喉镜未增加气道并发症风险。
核心结论
- 使用过滤式面罩2级或3级呼吸器与气道并发症风险增加相关,但多数其他气溶胶防护措施未改变风险。
研究设计与样本
- 前瞻性全国多中心队列研究,纳入70家医院96小时内接受全麻的成年患者5905例。
- 采用混合效应逻辑回归评估各气溶胶防护措施对总体及特定气道并发症的风险。
主要发现
- 气道并发症发生率为10.0%(95%CI 9.2-10.8%)。
- 过滤式面罩2级或3级呼吸器与气道并发症风险增加相关(OR 1.38,95%CI 1.04-1.83)。
- 该关联主要来自面罩通气困难(OR 1.68,95%CI 1.09-2.61)和脉搏血氧饱和度下降(OR 2.39,95%CI 1.26-4.54)。
- 护目镜、电动空气净化呼吸器、长袖隔离衣、双层手套和视频喉镜与气道并发症风险无显著关联。
关键数值与推荐
- 气道并发症总体发生率10.0%(95%CI 9.2-10.8%)。
- 过滤式面罩2级或3级呼吸器:气道并发症OR 1.38(95%CI 1.04-1.83),面罩通气困难OR 1.68(95%CI 1.09-2.61),血氧饱和度下降OR 2.39(95%CI 1.26-4.54)。
临床怎么用
- 临床应关注使用过滤式面罩2级或3级呼吸器时面罩通气困难和血氧饱和度下降的风险。
- 护目镜、电动空气净化呼吸器、长袖隔离衣、双层手套和视频喉镜未显示增加气道并发症风险。
局限性
- 研究未在模拟研究之外评估气溶胶防护对围术期气道并发症的风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The perceived risk of transmission of aerosolised viral particles from patients to airway practitioners during the COVID-19 pandemic led to the widespread use of aerosol precautions, including personal protective equipment and modifications to anaesthetic technique. The risk of these aerosol precautions on peri-operative airway complications has not been assessed outside of simulation studies. This prospective, national, multicentre cohort study aimed to quantify this risk. Adult patients undergoing general anaesthesia for elective or emergency procedures over a 96-hour period were included. Data collected included use of aerosol precautions by the airway practitioner, airway complications and potential confounding variables. Mixed-effects logistic regression was used to assess the risk of individual aerosol precautions on overall and specific airway complications. Data from 5905 patients from 70 hospital sites were included. The rate of airway complications was 10.0% (95%CI 9.2-10.8%). Use of filtering facepiece class 2 or class 3 respirators was associated with an increased risk of airway complications (odds ratio 1.38, 95%CI 1.04-1.83), predominantly due to an association with difficult facemask ventilation (odds ratio 1.68, 95%CI 1.09-2.61) and desaturation on pulse oximetry (odds ratio 2.39, 95%CI 1.26-4.54). Use of goggles, powered air-purifying respirators, long-sleeved gowns, double gloves and videolaryngoscopy were not associated with any alteration in the risk of airway complications. Overall, the use of filtering facepiece class 2 or class 3 respirators was associated with an increased risk of airway complications, but most aerosol precautions used during the COVID-19 pandemic were not.