文献速递区域麻醉与超声

区域麻醉超声图像解读辅助人工智能的外部验证研究

Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study.
PubMed 文献 · Br J Anaesth · 2022-08-18

本研究在40名志愿者九大解剖区域采集720段超声视频,由三位专家评估AI彩色叠加识别关键解剖结构的准确性及对不良事件或阻滞失败风险的影响。AI模型识别目标结构的率为93.5%(1519/1624),假阴性率3.0%,假阳性率3.5%。彩色叠加被判定在62.9%-86.4%的病例中降低神经、动脉、胸膜和腹膜误穿风险,81.3%的扫描中降低阻滞失败风险。

要点

  • AI彩色叠加识别目标结构的率为93.5%,假阴性率3.0%,假阳性率3.5%。
  • 彩色叠加在62.9%-86.4%的病例中降低误穿神经、动脉、胸膜和腹膜的风险。
  • 81.3%的扫描中彩色叠加降低阻滞失败风险,1.8%被认为增加风险。

核心结论

  • 基于人工智能的设备可能有助于超声引导区域麻醉的图像获取和解读。
  • 需要进一步研究证明其在支持培训和临床实践中的有效性。

研究设计与样本

  • 外部验证研究,由区域麻醉专家在不使用设备的情况下从40名志愿者九大解剖区域采集720段超声视频。
  • 随后应用AI彩色叠加,由另外三位专家独立评估每段视频(含原始未修改视频)以评估准确性及对感知风险的影响。

主要发现

  • AI模型识别目标结构的率为93.5%(1519/1624),假阴性率3.0%(48/1624),假阳性率3.5%(57/1624)。
  • 彩色叠加被判定降低神经、动脉、胸膜和腹膜误穿风险的比例为62.9%-86.4%(302/480至345/400),增加风险的比例为0.0%-1.7%(0/160至8/480)。
  • 阻滞失败风险在81.3%的扫描中(585/720)被认为降低,在1.8%(13/720)中被认为增加。

临床怎么用

  • AI彩色叠加可能辅助识别区域麻醉超声图像中的关键解剖结构。
  • 该技术可能有助于降低误穿神经、动脉、胸膜和腹膜的风险及阻滞失败风险。
  • 目前证据尚不足以支持其常规用于培训和临床实践,需进一步研究。

局限性

  • 研究为外部验证,需进一步研究证明其在培训和临床实践中的有效性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificial intelligence-based device that produces a colour overlay on real-time B-mode ultrasound to highlight anatomical structures of interest. We evaluated the accuracy of the artificial-intelligence colour overlay and its perceived influence on risk of adverse events or block failure. METHODS: Ultrasound-guided regional anaesthesia experts acquired 720 videos from 40 volunteers (across nine anatomical regions) without using the device. The artificial-intelligence colour overlay was subsequently applied. Three more experts independently reviewed each video (with the original unmodified video) to assess accuracy of the colour overlay in relation to key anatomical structures (true positive/negative and false positive/negative) and the potential for highlighting to modify perceived risk of adverse events (needle trauma to nerves, arteries, pleura, and peritoneum) or block failure. RESULTS: The artificial-intelligence models identified the structure of interest in 93.5% of cases (1519/1624), with a false-negative rate of 3.0% (48/1624) and a false-positive rate of 3.5% (57/1624). Highlighting was judged to reduce the risk of unwanted needle trauma to nerves, arteries, pleura, and peritoneum in 62.9-86.4% of cases (302/480 to 345/400), and to increase the risk in 0.0-1.7% (0/160 to 8/480). Risk of block failure was reported to be reduced in 81.3% of scans (585/720) and to be increased in 1.8% (13/720). CONCLUSIONS: Artificial intelligence-based devices can potentially aid image acquisition and interpretation in ultrasound-guided regional anaesthesia. Further studies are necessary to demonstrate their effectiveness in supporting training and clinical practice. CLINICAL TRIAL REGISTRATION: NCT04906018.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Bowness JS, Burckett-St Laurent D, Hernandez N, et al. Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study. Br J Anaesth. 2022. PMID: 35987706. doi:10.1016/j.bja.2022.06.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。