超声比注射压力监测更早识别低容量神经内注射
该尸体观察性研究评估超声引导下正中神经内注射时注射压力与神经肿胀的关系,假设神经肿胀先于注射压力升高(>15 psi)。33次注射中31次纳入分析,6次(19%)达到>15 psi(中位注射量0.6 mL),全部31次(100%)出现神经肿胀(中位注射量0.4 mL),解剖证实均为神经内扩散。结论:超声比注射压力监测更敏感、更早识别低容量神经内注射。
要点
- 神经肿胀在全部31次注射中出现,中位注射量0.4 mL。
- 注射压力>15 psi仅见于6次(19%),中位注射量0.6 mL。
- 超声比注射压力监测更敏感、更早识别神经内注射。
核心结论
- 超声是比注射压力监测更敏感、更早识别低容量神经内注射的指标。
研究设计与样本
- 观察性尸体研究,对11根未防腐人尸体正中神经行33次超声引导下神经内注射,于前臂近、中、远端各注射1 mL局麻药与亚甲蓝混合液,速率10 mL/min。
- 注射后解剖评估扩散位置,盲法分析操作视频与超声图像评估神经肿胀和注射压力。
- 31次注射纳入分析,2次因针尖位置不确定被排除。
主要发现
- 6次注射(19%)在注射压力>15 pound per square inch前达到中位注射量0.6 mL。
- 全部31次注射(100%)出现神经肿胀,中位注射量0.4 mL。
- 解剖证实所有注射的扩散位置均为神经内。
关键数值与推荐
- 注射压力升高阈值:>15 pound per square inch,由便携式串联监测器测量。
- 神经肿胀判定:超声图像盲法分析。
- 神经内扩散确认:注射后解剖评估亚甲蓝扩散位置。
临床怎么用
- 超声下神经肿胀可作为低容量神经内注射的早期警示征象,较注射压力监测更敏感。
- 注射压力监测未升高不能排除低容量神经内注射。
局限性
- 尸体研究,结果外推至活体需谨慎。
- 样本为离体正中神经,注射容量与速率固定。
- 2次注射因针尖位置不确定被排除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Inadvertent intraneural injection is not infrequent during peripheral nerve blocks. For this reason, injection pressure monitoring has been suggested as a safeguard method that warns the clinician of a potentially hazardous needle tip location. However, doubts remain whether it is superior to the sonographic nerve swelling in terms of earlier detection of the intraneural injection. METHODS: An observational cadaveric study was designed to assess injection pressures during an ultrasound-guided intraneural injection of the median nerve. We hypothesized that the evidence of nerve swelling occurred prior to an elevated injection pressure (>15 pound per square inch) measured with a portable in-line monitor. 33 ultrasound-guided intraneural injections of 11 median nerves from unembalmed human cadavers were performed at proximal, mid and distal forearm. 1 mL of a mixture of local anesthetic and methylene blue was injected intraneurally at a rate of 10 mL/min. Following injections, specimens were dissected to assess spread location. Video recordings of the procedures including ultrasound images were blindly analyzed to evaluate nerve swelling and injection pressures. RESULTS: 31 injections were considered for analysis (two were excluded due to uncertainty regarding needle tip position). >15 pound per square inch was reached in six injections (19%) following a median injected volume of 0.6 mL. Nerve swelling was evident in all 31 injections (100%) with a median injected volume of 0.4 mL. On dissection, spread location was confirmed intraneural in all injections. DISCUSSION: Ultrasound is a more sensitive and earlier indicator of the low-volume intraneural injection than injection pressure monitoring.