文献速递小儿麻醉气道管理

两种型号GlideScope视频喉镜片在婴儿气管插管中的比较:一项随机临床试验

Comparison of two sizes of GlideScope® blades in tracheal intubation of infants: a randomised clinicaltrial.
PubMed 文献 · Br J Anaesth · 2022-08-20

结果显示2号镜片插管时间更短(16[14-20]s vs 22[18-25]s,P=0.002),且导管尖端位于喉入口中心的比例更高(83% vs 40%,P<0.001)。结论认为2号镜片可显著缩短婴儿气管插管时间。

要点

  • 体重2.5-3.6kg婴儿使用GlideScope 2号镜片插管时间短于1号镜片。
  • 2号镜片组导管尖端位于喉入口中心的比例更高(83% vs 40%)。
  • 寻找导管尖端的时间与杓状软骨下缘距显示器中水平线的距离相关(r=0.28,P=0.033)。

核心结论

  • 与1号GlideScope镜片相比,使用2号镜片可显著缩短婴儿气管插管时间。

研究设计与样本

  • 主要结局为气管插管时间,并分析影响插管过程的喉镜视野相关因素。

主要发现

  • 2号镜片组插管时间中位数16[14-20]s,1号镜片组22[18-25]s,P=0.002,中位数差值-5,95%CI -7至-2。
  • 2号镜片组导管尖端位于喉入口中心的比例为83%,1号镜片组为40%,P<0.001。
  • 寻找导管尖端的时间与杓状软骨下缘距显示器中水平线的距离相关(r=0.28,P=0.033)。

临床怎么用

  • 对于体重2.5-3.6kg的婴儿,可优先选用GlideScope 2号镜片以缩短插管时间并提高导管尖端对准喉入口中心的成功率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The appropriate size of GlideScope® blade for tracheal intubation in neonates and premature infants has not been established. We evaluated the impact of the size of the GlideScope® blade on the time taken for intubation in infants weighing 2.5-3.6 kg. METHODS: Sixty infants weighing 2.5-3.6 kg were randomly assigned to use of the size 1 blade (n=30) or the size 2 blade (n=30). The primary outcome was the time taken to intubate. Components related to the laryngoscopic view which could affect the duration of the intubating process were also analysed. RESULTS: The time required for tracheal intubation was shorter with the size 2 blade than with the size 1 blade (16 [14-20] s vs 22 [18-25] s, P=0.002; median difference=-5; 95% confidence interval, -7 to -2). The rate at which the tip of the tracheal tube was located at the centre of the laryngeal inlet was higher with the size 2 blade than with the size 1 blade (83% vs 40%, P<0.001). Correlation analysis indicated that the time required to find the tip of the tube was related to how far the lower border of the arytenoid cartilages was located from the mid-horizontal line of the monitor (r=0.28, P=0.033). CONCLUSION: Use of the size 2 blade significantly reduced the time required to intubate the trachea, compared with the size 1 GlideScope® blade in infants. CLINICAL TRIAL REGISTRATION: KCT 0003867.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Kwon JH, Chung YJ, Her S, et al. Comparison of two sizes of GlideScope® blades in tracheal intubation of infants: a randomised clinicaltrial. Br J Anaesth. 2022. PMID: 35999074. doi:10.1016/j.bja.2022.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。