文献速递区域麻醉与超声

区域麻醉中创伤性针头神经损伤:一种新的机械转导假说

Traumatic needle damage to nerves during regional anesthesia: presentation of a novel mechanotransduction hypothesis.
PubMed 文献 · Reg Anesth Pain Med · 2022-07-25

该文提出机械转导假说,认为区域麻醉中针头暴力接触神经可通过激活Piezo离子通道和细胞内钙释放导致神经损伤。基于猪腋窝高分辨率超声和尸体组织学观察,短斜面22G阻滞针难以刺穿神经束,束膜内注射未必突破内膜。Thiel尸体实验显示穿破神经外膜所需力呈对数正态分布(0.6–16.8 N)。

要点

  • 短斜面22G针(0.7 mm宽)比平均神经束大三倍,神经束接触针时易滑开。
  • 穿破神经外膜所需力呈对数正态分布,范围为0.6–16.8 N。
  • 机械转导假说:暴力针伤可能通过Piezo受体激活和细胞内Ca2+释放致神经损伤。

核心结论

  • 机械转导可能参与区域麻醉后神经损伤,暴力针伤通过Piezo受体激活和细胞内钙释放介导。

研究设计与样本

  • 实验研究结合假说提出,使用猪腋窝高分辨率(75 µm)40 MHz微超声、新鲜尸体组织学及Thiel软防腐尸体测力。

主要发现

  • 短斜面22G、0.7 mm宽阻滞针是猪腋窝平均神经束大小的三倍,神经束在针接触时旋转难以刺穿。
  • 假定束内注射后组织学显示液体在束膜内和束内神经周隔扩散,但未突破内膜或轴突。
  • Thiel尸体穿破神经外膜的力呈对数正态分布,范围0.6 N至16.8 N。

关键数值与推荐

  • 高分辨率微超声频率为40 MHz,分辨率为75 µm。
  • 短斜面22G阻滞针宽度为0.7 mm。
  • 穿破神经外膜的力范围为0.6 N至16.8 N。

临床怎么用

  • 避免暴力针-神经接触,以降低机械转导相关神经损伤风险。

局限性

  • 机械转导假说基于实验观察提出,需进一步验证。
  • 有目的针插入相关力通常未知。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Despite advances in needle positioning techniques, nerve damage still occurs after regional anesthesia. Recognized causes include local anesthetic toxicity, subperineural injection, high subepineural fluid injection pressures and subepineural hematoma after forceful needle--nerve contact.We hypothesize that subperineural injection is still possible, but less likely to be the cause of nerve damage because needle penetration of fascicles and mechanical damage is difficult to achieve. High-resolution (75 µm) 40 MHz micro-ultrasound images of pig axillae show short-bevelled 22 g, 0.7 mm wide block needles that are three times larger than the average fascicle. Fascicular bundles are extremely difficult to puncture because they spin away on needle contact. Histology from fresh cadavers after supposed intrafascicular injection shows fluid spread within perineurium and intrafascicular perineural septae, but no breach of endoneurium or axons.We propose that mechanotransduction, the cellular changes that occur in response to force, contributes to nerve damage. Piezo ion channel proteins transduce force into electrical activity by rapid entry of cations into cells. Excessive Ca2+ influx into cells has the potential to inhibit nerve regeneration. Cellular changes include regulation of gene expression. The forces associated with purposeful needle insertion are generally unknown. Our experiments in the soft embalmed Thiel cadaver showed a lognormal range of forces between 0.6 N and 16.8 N on epineural penetration.We hypothesize that forceful needle injury may cause nerve damage by activation of Piezo receptors and release of intracellular Ca2.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. McLeod GA, Sadler A, Hales TG, et al. Traumatic needle damage to nerves during regional anesthesia: presentation of a novel mechanotransduction hypothesis. Reg Anesth Pain Med. 2022. PMID: 35878962. doi:10.1136/rapm-2022-103583

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。