视频喉镜与直接喉镜用于成人气管插管的Cochrane系统评价与Meta分析更新
结果显示任何设计的VL均可能降低插管失败率(Macintosh-style RR=0.41,95%CI 0.26-0.65;hyperangulated RR=0.51,95%CI 0.34-0.76;channelled RR=0.43,95%CI 0.30-0.61;中等确定性证据),提高首次插管成功率并改善声门视野,hyperangulated设计可能减少食管内插管。
要点
- 任何设计的VL均可能降低插管失败率(中等确定性证据)。
- VL提高首次插管成功率并改善声门视野。
- hyperangulated设计可能减少食管内插管并在困难气道特征患者中提高插管成功率(P=0.03)。
核心结论
- 在成人气管插管中,VL与更少的插管失败和低氧血症等并发症相关,同时声门视野改善。
研究设计与样本
- 按VL设计(Macintosh-style、hyperangulated、channelled)分别比较结局。
主要发现
- 任何设计的VL均可能降低插管失败率:Macintosh-style RR=0.41(95%CI 0.26-0.65),hyperangulated RR=0.51(95%CI 0.34-0.76),channelled RR=0.43(95%CI 0.30-0.61),中等确定性证据。
- VL提高首次插管成功率并改善声门视野。
- hyperangulated设计可能减少食管内插管,并在困难气道特征患者中提高插管成功率(P=0.03)。
关键数值与推荐
- 插管失败率:Macintosh-style RR=0.41(95%CI 0.26-0.65);hyperangulated RR=0.51(95%CI 0.34-0.76);channelled RR=0.43(95%CI 0.30-0.61);中等确定性证据。
- 困难气道特征患者中hyperangulated设计提高插管成功率(P=0.03)。
临床怎么用
- 成人气管插管时可优先考虑使用视频喉镜以降低插管失败风险。
- 对于困难气道特征患者,hyperangulated设计可能更有利于减少食管内插管并提高成功率。
局限性
- 多数研究至少一个领域存在不明确偏倚风险,所有研究存在高实施偏倚和检测偏倚风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Tracheal intubation is a commonly performed procedure that can be associated with complications and result in patient harm. Videolaryngoscopy (VL) may decrease this risk as compared with Macintosh direct laryngoscopy (DL). This review evaluates the risk and benefit profile of VL compared with DL in adults. METHODS: We searched MEDLINE, Embase, CENTRAL, and Web of Science on February 27, 2021. We included RCTs comparing VL with DL in patients undergoing tracheal intubation in any setting. We separately compared outcomes according to VL design: Macintosh-style, hyperangulated, and channelled. RESULTS: A total of 222 RCTs (with 26 149 participants) were included. Most studies had unclear risk of bias in at least one domain, and all were at high risk of performance and detection bias. We found that videolaryngoscopes of any design likely reduce rates of failed intubation (Macintosh-style: risk ratio [RR]=0.41; 95% confidence interval [CI], 0.26-0.65; hyperangulated: RR=0.51; 95% CI, 0.34-0.76; channelled: RR=0.43, 95% CI, 0.30-0.61; moderate-certainty evidence) with increased rates of successful intubation on first attempt and better glottic views across patient groups and settings. Hyperangulated designs are likely favourable in terms of reducing the rate of oesophageal intubation, and result in improved rates of successful intubation in individuals presenting with difficult airway features (P=0.03). We also present other patient-oriented outcomes. CONCLUSIONS: In this systematic review and meta-analysis of trials of adults undergoing tracheal intubation, VL was associated with fewer failed attempts and complications such as hypoxaemia, whereas glottic views were improved. SYSTEMATIC REVIEW REGISTRATION: This article is based on a Cochrane Review published in the Cochrane Database of Systematic Reviews (CDSR) 2022, Issue 4, DOI: 10.1002/14651858.CD011136.pub3 (see www.cochranelibrary.com for information). Cochrane Reviews are regularly updated as new evidence emerges and in response to feedback, and the CDSR should be consulted for the most recent version of the review.
引用
- Hansel J, Rogers AM, Lewis SR, et al. Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation: a Cochrane systematic review and meta-analysis update. Br J Anaesth. 2022. PMID: 35820934. doi:10.1016/j.bja.2022.05.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。