视频喉镜作为非选择手术患者气管插管首选技术:前后观察性研究
依从医院中,与干预前相比,干预后轻松气管插管比例从94.3%升至98.7%(+4.4%,95%CI 3.7-5.1%,P<0.001),所有次要结局比例显著降低;不依从医院无显著变化。
要点
- 将Macintosh型视频喉镜作为手术室气管插管首选设备与轻松插管比例显著提高相关。
- 依从医院干预后轻松插管比例98.7%,较干预前94.3%提高4.4%(95%CI 3.7-5.1%,P<0.001)。
- 不依从医院干预前后无显著变化,支持该改进措施的效果。
核心结论
- 在手术室将Macintosh型视频喉镜作为气管插管首选设备,与标准Macintosh喉镜相比,轻松气管插管比例显著增加。
主要发现
- 依从医院干预后轻松气管插管比例为98.7%(4547/4606),干预前为94.3%(5177/5487),提高4.4%(95%CI 3.7-5.1%,P<0.001)。
- 与干预前相比,干预后所有次要结局比例显著降低。
- 不依从医院干预前后无显著变化。
临床怎么用
- 在手术室对非选择成人手术患者,可考虑将Macintosh型视频喉镜作为气管插管首选设备以提高轻松插管比例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Using a Macintosh-style videolaryngoscope as a first-intention device for tracheal intubation of unselected patients in the operating room has not often been studied. We hypothesised that using a Macintosh-style videolaryngoscope as a first-intention device is associated with an increased proportion of easy tracheal intubation. METHODS: In a quality improvement project for airway management aimed at implementing a Macintosh-style videolaryngoscope as a first-intention device, we included all consecutive tracheal intubations in adults from March, 2017 to September, 2020 in two French teaching hospitals. We divided the cohort into three temporal cohorts: the pre-intervention, implementation, and post-intervention periods. The primary outcome was the proportion of easy airway management. The secondary outcomes were the rescue technique, Cormack-Lehane III or IV view, and operator-reported difficulty of intubation. Data from one hospital compliant with the quality improvement project were compared with data from a non-compliant hospital. RESULTS: A total of 26 692 tracheal intubations were performed. Among 11 938 intubations included in the compliant hospital, 5487 were included in the pre-intervention, 1845 in the implementation, and 4606 in the post-intervention periods. In comparison to the pre-intervention period, the proportions of easy tracheal intubation increased from 94.3% (5177 of 5487) to 98.7% (4547 of 4606)) in the post-intervention period (+4.4% [95% confidence interval 3.7-5.1%], P<0.001). In comparison to the pre-intervention period, all secondary outcome proportions were significantly lower in the post-intervention period. No significant changes were noted in the non-compliant hospital between the pre- and post-intervention periods. CONCLUSIONS: Using a Macintosh-style videolaryngoscope as a first-intention device for tracheal intubation in the operating room was associated with a significant increase in the proportion of easy tracheal intubation, compared with use of the standard Macintosh laryngoscope.
引用
- De Jong A, Sfara T, Pouzeratte Y, et al. Videolaryngoscopy as a first-intention technique for tracheal intubation in unselected surgical patients: a before and after observational study. Br J Anaesth. 2022. PMID: 35811139. doi:10.1016/j.bja.2022.05.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。