文献速递气道管理

呼气末正压对喉罩漏气与氧合的影响:一项随机试验

The Influence of Positive End-Expiratory Pressure on Leakage and Oxygenation Using a Laryngeal Mask Airway: A Randomized Trial.
PubMed 文献 · Anesth Analg · 2022-06-20

该前瞻性、随机、单盲、多中心试验纳入ASA I/II级择期全麻喉罩通气患者,比较PEEP 8 mbar与ZEEP对气体泄漏和氧合的影响。结果显示两组气体泄漏发生率无差异,但PEEP组需重新置入喉罩的比例更高,25分钟后SpO2和动态顺应性更高。

要点

  • PEEP 8 mbar未增加喉罩通气总体气体泄漏发生率。
  • PEEP组需重新置入喉罩的比例显著高于ZEEP组。
  • PEEP组25分钟后SpO2和动态顺应性更高,但临床获益有限。

核心结论

  • PEEP 8 mbar未影响喉罩正压通气时气体泄漏的总体发生率。
  • PEEP组重新置入喉罩的发生率高于ZEEP组,但抢救性插管率无差异。
  • PEEP 8 mbar轻微改善氧合和顺应性,但研究未提供择期手术喉罩通气常规使用PEEP的强有力依据。

研究设计与样本

  • 前瞻性、对照、随机、单盲、多中心临床 trial。
  • 纳入年龄>18岁、ASA I/II级、无较高误吸风险、计划在喉罩全麻下择期手术的患者。
  • 患者随机分为ZEEP对照组或PEEP 8 mbar干预组,均接受正压通气。
  • 主要终点为气体泄漏的发生。
  • ZEEP组174例,PEEP组208例。

临床怎么用

  • 择期手术喉罩正压通气时,使用PEEP 8 mbar需权衡重新置入喉罩风险与氧合改善的有限获益。
  • 对于氧合或顺应性需要改善的患者,可考虑PEEP但应警惕喉罩密封性下降。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The value of positive end-expiratory pressure (PEEP) in maintaining oxygenation during ventilation with a laryngeal mask airway (LMA) mask is unclear. To clarify the potential benefit or harm to PEEP application during positive pressure ventilation with a ProSeal LMA® mask, we compared the effect of PEEP versus zero end-expiratory pressure (ZEEP) on gas leakage and oxygenation. We hypothesized that a PEEP of 8 mbar (8.2 cm H 2 O) would be associated with an increased incidence of gas leakage compared to ZEEP. METHODS: We designed a prospective, controlled, randomized, single-blinded, multicenter clinical trial. Patients >18 years of age with an American Society of Anesthesiologists (ASA) physical status I/II without increased risk of aspiration were enrolled if they were scheduled for elective surgery under general anesthesia with an LMA mask. Patients were randomized to a control group managed with ZEEP or an intervention group managed with a PEEP of 8 mbar. Both groups received positive pressure ventilation. The primary end point was the occurrence of gas leakage. The Student t test and χ 2 test were used for statistical analysis. RESULTS: A total of 174 patients were enrolled in the ZEEP group, and 208 were enrolled in the PEEP group. The incidence of gas leakage did not differ between the 2 groups (ZEEP: 23/174, 13.2%; PEEP: 42/208, 20.2%; P = .071; odds ratio [OR], 1.611; 95% confidence interval [CI], 0.954-2.891). However, more patients required reseating of the LMA mask in the PEEP group (ZEEP: 5/174, 2.9%; PEEP: 18/208, 8.7%; P = .018; OR, 3.202; 95% CI, 1.164-8.812). The need for endotracheal intubation did not differ between groups (ZEEP: 2/174, 1.1%; PEEP: 7/208, 3.4%; P = .190; OR, 2.995; 95% CI, 0.614-14.608). After positive pressure ventilation for 25 minutes, the mean peripheral oxygen saturation (Sp o2 ) was higher in the PEEP than in the ZEEP group (98.5 [1.9]% vs 98.0 [1.4]%; P = .01). Peak inspiratory pressure (PIP; 16 [2] vs 12 [4] mbar; P < .001) and dynamic compliance (57 [14] vs 49 [14] mL/mbar; P < .001) were both higher in the PEEP group than in the ZEEP group. CONCLUSIONS: Use of PEEP did not affect the overall incidence of gas leakage. However, PEEP did result in a higher incidence of attempts to reseat the LMA mask compared to ZEEP, whereas the incidence of rescue intubation did not differ between groups. We concluded that a PEEP of 8 mbar did not increase overall gas leakage during positive pressure ventilation with an LMA mask, but it did slightly improve gas exchange and compliance. Overall, our study does not provide strong arguments for using PEEP during ventilation with an LMA mask in elective surgery.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Ullmann H, Renziehausen L, Geil D, et al. The Influence of Positive End-Expiratory Pressure on Leakage and Oxygenation Using a Laryngeal Mask Airway: A Randomized Trial. Anesth Analg. 2022. PMID: 35726893. doi:10.1213/ANE.0000000000006115

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。