结果显示体外循环期间MDPE为-1.8%、MDAPE为14.0%,模型预测准确。

要点

  • 体外循环期间Minto模型MDPE为-1.8%,MDAPE为14.0%,预测性能良好。
  • 体外循环前MDPE为-17.3%,MDAPE为24.6%,预测偏差大于体外循环期间。
  • 年龄、术前白蛋白、温度和血液稀释与MDAPE>30%无独立关联。

核心结论

  • Minto模型在体外循环心脏手术期间能准确预测瑞芬太尼血浆浓度。

主要发现

  • 体外循环前MDPE为-17.3%[-32.9至2.3],MDAPE为24.6%[12至37.7]%。
  • 体外循环期间MDPE为-1.8%[-15.6至11.1]%,MDAPE为14.0%[6.74至27.1]%。
  • 体外循环期间实测与预测瑞芬太尼血浆浓度差异无统计学意义。
  • 年龄、术前白蛋白浓度、温度和血液稀释与MDAPE>30%无独立关联。

临床怎么用

  • 体外循环心脏手术中可依据Minto模型靶控输注瑞芬太尼,但体外循环前预测偏差较大需注意。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Minto pharmacokinetic model is used for target-controlled infusion of remifentanil. The reliability of this model has never been evaluated during normothermic cardiac surgery with cardiopulmonary bypass (CPB). The aim of this study was to assess the predictive performance of the model during CPB to determine its reliability during cardiac surgery. METHODS: This was a single-centre observational study. Arterial blood samples were drawn at five time points: T1, after tracheal intubation; T2, immediately before CPB; T3, 10 min after starting CPB; T4, 45 min after starting CPB; T5, 10 min after weaning off CPB. Prediction error (PE) and absolute prediction error (APE) were calculated for each sample and used to determine median prediction error (MDPE) and median absolute prediction error (MDAPE) per patient. Risk factors for APE >30% were assessed using multivariable analysis. Results are presented as medians with inter-quartile ranges. RESULTS: Fifty-eight patients with 283 blood samples (110 during CPB) were included. In the pre-CPB period, MDPE and MDAPE were -17.3 [-32.9 to 2.3] and 24.6 [12-37.7]%, whereas during CPB, they were -1.8 [-15.6 to 11.1] and 14.0 [6.74-27.1]%, respectively. There was no statistically significant difference between measured and predicted remifentanil plasma concentrations during CPB. Age, preoperative albumin concentrations, temperature, and haemodilution were not independently associated with MDAPE >30%. CONCLUSIONS: The Minto model accurately predicts plasma remifentanil concentrations during cardiac surgery with CPB. CLINICAL TRIAL REGISTRATION: 2017-A03153-50.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Scherrer V, Lamoureux F, Chaventre C, et al. Reliability of the Minto model for target-controlled infusion of remifentanil during cardiac surgery with cardiopulmonary bypass. Br J Anaesth. 2022. PMID: 35750514. doi:10.1016/j.bja.2022.05.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。