文献速递产科麻醉区域麻醉与超声

肥胖产妇硬膜穿刺硬膜外与标准硬膜外分娩镇痛质量比较:双盲随机对照研究

Quality of Labor Analgesia with Dural Puncture Epidural versus Standard Epidural Technique in Obese Parturients: A Double-blind Randomized Controlled Study.
PubMed 文献 · Anesthesiology · 2022-01-01

本研究为双盲随机对照试验,纳入BMI≥35 kg·m⁻²的足月初产妇,比较硬膜穿刺硬膜外技术(25G Whitacre针)与标准硬膜外技术的分娩镇痛质量。主要复合结局(不对称阻滞、硬膜外追加、导管调整、导管更换、剖宫产区域麻醉失败)在两组间无统计学或临床显著差异(52% vs 49%;OR 1.1 [0.5–2.4];P=0.766),次要结局亦无差异。结论不支持在肥胖产妇中常规使用硬膜穿刺硬膜外技术。

要点

  • 肥胖产妇中硬膜穿刺硬膜外与标准硬膜外的分娩镇痛质量无差异。
  • 主要复合结局发生率两组相近(52% vs 49%;OR 1.1;P=0.766)。
  • 不推荐在肥胖产妇中常规采用硬膜穿刺硬膜外技术。

核心结论

  • 在肥胖产妇中,硬膜穿刺硬膜外技术与标准硬膜外技术的分娩镇痛质量无差异,不支持常规使用硬膜穿刺硬膜外技术。

研究设计与样本

  • 双盲随机对照研究,纳入BMI≥35 kg·m⁻²、宫口扩张2–7 cm、疼痛评分>4的足月初产妇,随机分为硬膜穿刺硬膜外组(25G Whitacre针)或标准硬膜外组。
  • 共随机141例,每组66例纳入分析。

主要发现

  • 主要复合结局的各个组分及所有次要结局在两组间均无统计学或临床显著差异。

关键数值与推荐

  • 镇痛启动方案:0.1%罗哌卡因15 ml含芬太尼2 µg·ml⁻¹,随后程序化间歇推注(每45分钟6 ml)联合患者自控硬膜外镇痛。

临床怎么用

  • 对于肥胖产妇,选择硬膜穿刺硬膜外技术并未显示优于标准硬膜外技术,临床可继续采用标准硬膜外技术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The dural puncture epidural technique may improve analgesia quality by confirming midline placement and increasing intrathecal translocation of epidural medications. This would be advantageous in obese parturients with increased risk of block failure. This study hypothesizes that quality of labor analgesia will be improved with dural puncture epidural compared to standard epidural technique in obese parturients. METHODS: Term parturients with body mass index greater than or equal to 35 kg · m-2, cervical dilation of 2 to 7 cm, and pain score of greater than 4 (where 0 indicates no pain and 10 indicates the worst pain imaginable) were randomized to dural puncture epidural (using 25-gauge Whitacre needle) or standard epidural techniques. Analgesia was initiated with 15 ml of 0.1% ropivacaine with 2 µg · ml-1 fentanyl, followed by programed intermittent boluses (6 ml every 45 min), with patient-controlled epidural analgesia. Parturients were blinded to group allocation. The data were collected by blinded investigators every 3 min for 30 min and then every 2 h until delivery. The primary outcome was a composite of (1) asymmetrical block, (2) epidural top-ups, (3) catheter adjustments, (4) catheter replacement, and (5) failed conversion to regional anesthesia for cesarean delivery. Secondary outcomes included time to a pain score of 1 or less, sensory levels at 30 min, motor block, maximum pain score, patient-controlled epidural analgesia use, epidural medication consumption, duration of second stage of labor, delivery mode, fetal heart tones changes, Apgar scores, maternal adverse events, and satisfaction with analgesia. RESULTS: Of 141 parturients randomized, 66 per group were included in the analysis. There were no statistically or clinically significant differences between the dural puncture epidural and standard epidural groups in the primary composite outcome (34 of 66, 52% vs. 32 of 66, 49%; odds ratio, 1.1 [0.5 to 2.4]; P = 0.766), its individual components, or any of the secondary outcomes. CONCLUSIONS: A lack of differences in quality of labor analgesia between the two techniques in this study does not support routine use of the dural puncture epidural technique in obese parturients.

来源:Anesthesiology,查看原文。版权归原作者所有。

引用

  1. Tan HS, Reed SE, Mehdiratta JE, et al. Quality of Labor Analgesia with Dural Puncture Epidural versus Standard Epidural Technique in Obese Parturients: A Double-blind Randomized Controlled Study. Anesthesiology. 2022. PMID: 35157756. doi:10.1097/ALN.0000000000004137

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。