超声测定早产儿硬膜囊至骶尾膜距离
本研究对40名早产儿在左侧卧位下进行骶部超声成像,测量骶尾膜至硬膜囊远端距离。平均距离为17.4 mm(标准差3.1,范围10.6-26.3),体重与距离正相关但变异系数大(23%)。超声可测量该距离并显示较大变异性,可能识别硬膜穿刺风险患者;无超声时,进针超过骶尾膜穿刺点小于3 mm/kg可预防99.9%新生儿硬膜接触。
要点
- 早产儿骶尾膜至硬膜囊距离平均17.4 mm,变异大。
- 体重与距离正相关,但变异系数23%。
- 无超声时,进针深度小于3 mm/kg可避免硬膜接触。
核心结论
- 超声可用于早产儿骶管阻滞前测量骶尾膜至硬膜囊距离,显示较大变异性,可能识别硬膜穿刺风险患者。
研究设计与样本
- 对40名早产儿(20男20女)在左侧卧位下进行骶部超声成像,未进行穿刺,测量骶尾膜至硬膜囊远端距离,记录脊髓圆锥和硬膜囊终止的脊柱水平。
主要发现
- 平均体重1740 g(标准差290,范围860-2350),平均胎龄35.0周(标准差1.35,范围32.2-39)。
- 平均骶尾膜至硬膜囊远端距离为17.4 mm(标准差3.1,范围10.6-26.3)。
- 体重与距离正相关,但变异系数大为23%。
- 脊髓圆锥终止低于L3水平者占20%,硬膜囊终止低于S3水平者占10%(髋关节屈曲时)。
关键数值与推荐
- 无超声时,进针超过骶尾膜穿刺点小于3 mm/kg可预防99.9%新生儿硬膜接触。
临床怎么用
- 早产儿骶管阻滞前可使用超声测量骶尾膜至硬膜囊距离以评估硬膜穿刺风险。
- 若无超声,进针深度应小于3 mm/kg(超过骶尾膜穿刺点)以避免硬膜接触。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Caudal epidural analgesia is the most common regional anesthetic performed in infants. Dural puncture, the most common serious complication, is inversely proportional to age. Measuring the distance from the sacrococcygeal membrane to the dural sac may prevent dural puncture. This study measures the sacrococcygeal membrane to dural sac distance using ultrasound imaging to determine feasibility of imaging and obtaining measurements. METHODS: Sacral ultrasound imaging of 40 preterm neonates was obtained in left lateral decubitus, a typical position for caudal blockade. No punctures were made. The sacrococcygeal membrane and termination of the dural sac were visualized, and the distance measured. The spinal levels of the conus medullaris and dural sac termination were recorded. RESULTS: 20 males and 20 females former preterm neonates with an average weight (SD; range) of 1740 (290; 860-2350) g and average age (SD; range) of 35.0 (1.35; 32.2-39) weeks gestational age at the time of imaging. The average sacrococcygeal membrane to distal dural sac distance (SD; range) was 17.4 (3.1; 10.6-26.3) mm. Overall, the weights correlated positively with the distance but the coefficient of variation was large at 23%. The conus medularis terminated below the L3 level and dural sac below the S3 level in 20% and 10% of subjects respectively with hip flexion. CONCLUSION: Ultrasound can be used to measure the sacrococcygeal membrane to dura distance in preterm neonates prior to needle insertion when performing caudal block and demonstrates large variability. Ultrasound imaging may identify patients at risk for dural puncture. When ultrasound is not available, needle insertion less than 3 mm/kg beyond the puncture of the sacrococcygeal membrane should prevent dural contact in 99.9% of neonates.
引用
- Ponde V, Shah D, Nagdev T, et al. Ultrasound determination of the dural sac to sacrococcygeal membrane distance in premature neonates. Reg Anesth Pain Med. 2022. PMID: 35115413. doi:10.1136/rapm-2021-103344
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。