文献速递产科麻醉气道管理术前评估与围术期医学

剖宫产全麻困难插管的发生率与危险因素:多中心回顾性队列分析

Frequency and Risk Factors for Difficult Intubation in Women Undergoing General Anesthesia for Cesarean Delivery: A Multicenter Retrospective Cohort Analysis.
PubMed 文献 · Anesthesiology · 2022-01-01

该多中心回顾性队列研究利用MPOG数据库纳入2004至2019年间45家医疗中心14,748例15至44岁剖宫产全麻病例,评估困难插管与插管失败频率及危险因素。困难插管频率为1:49(95%CI 1:55至1:44),插管失败频率为1:808(95%CI 1:1,276至1:511)。危险因素多为非产科因素,包括BMI增高、Mallampati III或IV级、颏至舌骨距离小、下颌前突受限、张口受限及颈椎活动受限。

要点

  • 剖宫产全麻困难插管频率为1:49,插管失败为1:808。
  • 危险因素以非产科因素为主,如BMI增高和Mallampati III或IV级。
  • 产科困难插管仍是持续存在的临床问题。

核心结论

  • 在超过14,000例剖宫产全麻的多中心 contemporary 研究中,困难插管总体风险为1:49,插管失败风险为1:808。
  • 大多数困难插管的危险因素为非产科性质,产科困难插管仍是持续关注的问题。

研究设计与样本

  • 多中心回顾性队列研究,利用Multicenter Perioperative Outcomes Group数据库。
  • 纳入2004至2019年间45家医疗中心15至44岁剖宫产全麻女性,共14,748例。

主要发现

  • 困难插管295例,频率1:49(95%CI 1:55至1:44;n=14,531)。
  • 插管失败18例,频率1:808(95%CI 1:1,276至1:511;n=14,537)。
  • 困难插管 odds 点估计最高的因素包括BMI增高、Mallampati III或IV级、颏至舌骨距离小、下颌前突受限、张口受限及颈椎活动受限。

关键数值与推荐

  • 困难插管定义:Cormack-Lehane分级3级或以上、三次或以上插管尝试、补救纤维支气管镜插管、补救声门上气道或外科气道。
  • 插管失败定义:任何插管尝试均未成功置入气管导管。

临床怎么用

  • 剖宫产全麻术前应评估BMI、Mallampati分级、颏至舌骨距离、下颌前突、张口度及颈椎活动度以识别困难插管高风险患者。
  • 对存在上述非产科危险因素者应做好困难气道预案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Estimates for the incidence of difficult intubation in the obstetric population vary widely, although previous studies reporting rates of difficult intubation in obstetrics are older and limited by smaller samples. The goals of this study were to provide a contemporary estimate of the frequency of difficult and failed intubation in women undergoing general anesthesia for cesarean delivery and to elucidate risk factors for difficult intubation in women undergoing general anesthesia for cesarean delivery. METHODS: This is a multicenter, retrospective cohort study utilizing the Multicenter Perioperative Outcomes Group database. The study population included women aged 15 to 44 yr undergoing general anesthesia for cesarean delivery between 2004 and 2019 at 1 of 45 medical centers. Coprimary outcomes included the frequencies of difficult and failed intubation. Difficult intubation was defined as Cormack-Lehane view of 3 or greater, three or more intubation attempts, rescue fiberoptic intubation, rescue supraglottic airway, or surgical airway. Failed intubation was defined as any attempt at intubation without successful endotracheal tube placement. The rates of difficult and failed intubation were assessed. Several patient demographic, anatomical, and obstetric factors were evaluated for potential associations with difficult intubation. RESULTS: This study identified 14,748 cases of cesarean delivery performed under general anesthesia. There were 295 cases of difficult intubation, with a frequency of 1:49 (95% CI, 1:55 to 1:44; n = 14,531). There were 18 cases of failed intubation, with a frequency of 1:808 (95% CI, 1:1,276 to 1:511; n = 14,537). Factors with the highest point estimates for the odds of difficult intubation included increased body mass index, Mallampati score III or IV, small hyoid-to-mentum distance, limited jaw protrusion, limited mouth opening, and cervical spine limitations. CONCLUSIONS: In this large, multicenter, contemporary study of more than 14,000 general anesthetics for cesarean delivery, an overall risk of difficult intubation of 1:49 and a risk of failed intubation of 1:808 were observed. Most risk factors for difficult intubation were nonobstetric in nature. These data demonstrate that difficult intubation in obstetrics remains an ongoing concern.

来源:Anesthesiology,查看原文。版权归原作者所有。

引用

  1. Reale SC, Bauer ME, Klumpner TT, et al. Frequency and Risk Factors for Difficult Intubation in Women Undergoing General Anesthesia for Cesarean Delivery: A Multicenter Retrospective Cohort Analysis. Anesthesiology. 2022. PMID: 35188971. doi:10.1097/ALN.0000000000004173

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。