文献速递小儿麻醉神经外科与老年麻醉

婴儿麻醉诱导期脑电α功率降低与脑电不连续相关

Decreased Electroencephalographic Alpha Power During Anesthesia Induction Is Associated With EEG Discontinuity in Human Infants.
PubMed 文献 · Anesth Analg · 2022-11-16

BACKGROUND: Electroencephalogram (EEG) discontinuity can occur at high concentrations of anesthetic drugs, reflecting suppression of electrocortical activity. This EEG pattern has been reported in children and reflects a deep state of anesthesia.…

要点

  • 婴儿麻醉诱导期脑电不连续常见(37%),与七氟烷诱导的后部α功率降低独立相关。
  • 该关联仅在麻醉状态下出现,基线脑电无差异,提示麻醉可能揭示隐藏的脑网络属性。
  • 麻醉中神经生理标志物或有助于识别脑电不连续风险更高的婴儿。

核心结论

  • 婴儿麻醉诱导期脑电不连续常见,且与七氟烷诱导的后部α功率降低独立相关。
  • 该关联在调整年龄和丙泊酚合用后仍存在,且仅见于麻醉状态而非基线脑电。

研究设计与样本

  • 前瞻性观察队列研究,纳入54名神经正常婴儿(中位年龄7.6个月,IQR 4.9-9.8个月),麻醉诱导期记录26导联脑电。

主要发现

  • 54名婴儿中20名(37%)出现脑电不连续,共25次离散事件。
  • 两组基线(未麻醉)脑电α功率及其他频段功率无差异。

关键数值与推荐

  • 脑电不连续定义为电压振幅<25微伏持续>2秒。
  • α功率为七氟烷诱导的8-12 Hz功率,后部区域以中线顶区(Pz)为代表。

临床怎么用

  • 婴儿麻醉诱导期应关注脑电不连续现象,其与后部α功率降低相关,或提示皮层-丘脑回路发育差异。

局限性

  • 原文未明确报告局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Electroencephalogram (EEG) discontinuity can occur at high concentrations of anesthetic drugs, reflecting suppression of electrocortical activity. This EEG pattern has been reported in children and reflects a deep state of anesthesia. Isoelectric events on the EEG, a more extreme degree of voltage suppression, have been shown to be associated with worse long-term neurologic outcomes in neonates undergoing cardiac surgery. However, the clinical significance of EEG discontinuities during pediatric anesthesia for noncardiac surgery is not yet known and merits further research. In this study, we assessed the incidence of EEG discontinuity during anesthesia induction in neurologically normal infants and the clinical factors associated with its development. We hypothesized that EEG discontinuity would be associated with sevoflurane-induced alpha (8-12 Hz) power during the period of anesthesia induction in infants. METHODS: We prospectively recorded 26 channels of EEG during anesthesia induction in an observational cohort of 54 infants (median age, 7.6 months; interquartile range [IQR] [4.9-9.8 months]). We identified EEG discontinuity, defined as voltage amplitude <25 microvolts for >2 seconds, and assessed its association with sevoflurane-induced alpha power using spectral analysis and multivariable logistic regression adjusting for clinically important variables. RESULTS: EEG discontinuity was observed in 20 of 54 subjects (37%), with a total of 25 discrete events. Sevoflurane-induced alpha power in the posterior regions of the head (eg, parietal or occipital regions) was significantly lower in the EEG discontinuity group (midline parietal channel on the electroencephalogram, International 10-20 System [Pz]; 8.3 vs 11.2 decibels [dBs]; P = .004), and this association remained after multivariable adjustment (adjusted odds ratio [aOR] = 0.51 per dB increase in alpha power [95% CI, 0.30-0.89]; P = .02). There were no differences in the baseline (unanesthetized) EEG between groups in alpha power or power in any other frequency band. CONCLUSIONS: We demonstrate that EEG discontinuity is common during anesthesia induction and is related to the level of sevoflurane-induced posterior alpha power, a putative marker of cortical-thalamic circuit development in the first year of life. This association persisted even after adjusting for age and propofol coadministration. The fact that this difference was only observed during anesthesia and not in the baseline EEG suggests that otherwise hidden brain circuit properties are unmasked by general anesthesia. These neurophysiologic markers observed during anesthesia may be useful in identifying patients who may have a greater chance of developing discontinuity.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Chao JY, Gutiérrez R, Legatt AD, et al. Decreased Electroencephalographic Alpha Power During Anesthesia Induction Is Associated With EEG Discontinuity in Human Infants. Anesth Analg. 2022. PMID: 35041633. doi:10.1213/ANE.0000000000005864

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。