颈丛阻滞深度与膈神经阻滞:一项随机试验

Depth of cervical plexus block and phrenic nerve blockade: a randomized trial.
PubMed 文献 · Reg Anesth Pain Med · 2022-01-10

本研究为观察者盲法随机对照试验,纳入45例择期清醒颈动脉内膜切除术患者,比较深、中、浅颈丛阻滞对膈肌运动的影响。主要结局为组间同侧膈肌用力吸气时位移差异,术后三组分别为4.34±1.06、3.86±1.24、2.04±1.20 cm(浅、中、深,P<0.001),深组膈肌功能障碍最明显,肺功能、氧饱和度、并发症及满意度无差异。

要点

  • 深颈丛阻滞组同侧膈肌用力吸气位移最小,膈肌功能障碍最明显。
  • 三组肺功能、氧饱和度、并发症率和患者满意度无差异。
  • MRI显示药液可跨浅筋膜渗透,但仍可区分目标间隙内扩散。

核心结论

  • 颈丛阻滞深度影响膈神经阻滞程度,深颈丛阻滞组膈肌功能障碍最明显。

研究设计与样本

  • 观察者盲法随机对照试验,纳入45例择期清醒颈动脉内膜切除术患者,随机接受深、中、浅颈丛阻滞,每例使用20 mL 0.5%罗哌卡因混合MRI对比剂。

主要发现

  • 术后同侧膈肌用力吸气位移(浅、中、深组均值±SD)分别为4.34±1.06、3.86±1.24、2.04±1.20 cm,组间差异有统计学意义(P<0.001)。
  • 正常吸气时也观察到组间差异。
  • 肺功能、氧饱和度、并发症率和患者满意度组间无差异。
  • MRI显示药液明显渗透跨浅筋膜,但仍可清晰区分目标间隙内的扩散。

临床怎么用

  • 清醒颈动脉内膜切除术行颈丛阻滞时,选择深颈丛阻滞需警惕同侧膈肌功能障碍。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Cervical plexus blocks are commonly used to facilitate carotid endarterectomy (CEA) in the awake patient. These blocks can be divided into superficial, intermediate, and deep blocks by their relation to the fasciae of the neck. We hypothesized that the depth of block would have a significant impact on phrenic nerve blockade and consequently hemi-diaphragmatic motion. METHODS: We enrolled 45 patients in an observer blinded randomized controlled trial, scheduled for elective, awake CEA. Patients received either deep, intermediate, or superficial cervical plexus blocks, using 20 mL of 0.5% ropivacaine mixed with an MRI contrast agent. Before and after placement of the block, transabdominal ultrasound measurements of diaphragmatic movement were performed. Patients underwent MRI of the neck to evaluate spread of the injectate, as well as lung function measurements. The primary outcome was ipsilateral difference of hemi-diaphragmatic motion during forced inspiration between study groups. RESULTS: Postoperatively, forced inspiration movement of the ipsilateral diaphragm (4.34±1.06, 3.86±1.24, 2.04±1.20 (mean in cm±SD for superficial, intermediate and deep, respectively)) was statistically different between block groups (p<0.001). Differences were also seen during normal inspiration. Lung function, oxygen saturation, complication rates, and patient satisfaction did not differ. MRI studies indicated pronounced permeation across the superficial fascia, but nevertheless easily distinguishable spread of injectate within the targeted compartments. CONCLUSIONS: We studied the characteristics and side effects of cervical plexus blocks by depth of injection. Diaphragmatic dysfunction was most pronounced in the deep cervical plexus block group. TRIAL REGISTRATION NUMBER: EudraCT 2017-001300-30.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Opperer M, Kaufmann R, Meissnitzer M, et al. Depth of cervical plexus block and phrenic nerve blockade: a randomized trial. Reg Anesth Pain Med. 2022. PMID: 35012992. doi:10.1136/rapm-2021-102851

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。