文献速递术前评估与围术期医学气道管理

爆炸肺损伤合并失血性休克院前持续气道正压通气的建模研究

Pre-hospital continuous positive airway pressure after blast lung injury and hypovolaemic shock: a modelling study.
PubMed 文献 · Br J Anaesth · 2021-12-02

本研究通过基于已发表猪实验校准的计算机模拟,评估院前CPAP对爆炸肺损伤合并失血性休克的作用。模拟显示,轻度和中度损伤时5-10 cm H2O CPAP可改善PaO2,但严重损伤时CPAP超过10 cm H2O因血流动力学受损反而降低PaO2。

要点

  • 轻度爆炸肺损伤:5 cm H2O CPAP提升PaO2,更高水平无额外获益。
  • 中度损伤:10 cm H2O CPAP改善PaO2,15 cm H2O无进一步获益。
  • 严重损伤:5 cm H2O CPAP改善氧合,10-15 cm H2O因血流动力学受损降低PaO2。

核心结论

  • 模拟研究提示,环境空气5 cm H2O CPAP可能对爆炸肺损伤伤员有益,即使合并严重失血性休克。
  • 严重肺损伤后CPAP超过10 cm H2O因血流动力学受损而降低氧输送。

研究设计与样本

  • 基于计算机模拟的心肺反应模型,校准自已发表的猪爆炸伤和失血性休克对照实验。
  • 模拟了3例虚拟患者,分别有轻度、中度、重度爆炸肺损伤(肺挫伤面积10%、25%、50%)合并失血性休克。

主要发现

  • 轻度爆炸肺损伤:5 cm H2O环境空气CPAP使PaO2从10.6 kPa升至12.6 kPa,更高CPAP未进一步改善。
  • 中度爆炸肺损伤:10 cm H2O CPAP使PaO2从8.5 kPa升至11.1 kPa,15 cm H2O无额外获益。
  • 重度爆炸肺损伤:5 cm H2O CPAP使PaO2从4.06 kPa升至8.39 kPa,10和15 cm H2O分别降至7.99和7.90 kPa。

临床怎么用

  • 对爆炸肺损伤合并失血性休克伤员,可考虑院前使用5 cm H2O CPAP改善氧合。
  • 严重肺损伤时避免CPAP超过10 cm H2O,以防血流动力学受损。

局限性

  • 研究为计算机模拟,结论需临床研究验证。
  • 模型基于猪实验数据校准,外推至人类需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In non-traumatic respiratory failure, pre-hospital application of CPAP reduces the need for intubation. Primary blast lung injury (PBLI) accompanied by haemorrhagic shock is common after mass casualty incidents. We hypothesised that pre-hospital CPAP is also beneficial after PBLI accompanied by haemorrhagic shock. METHODS: We performed a computer-based simulation of the cardiopulmonary response to PBLI followed by haemorrhage, calibrated from published controlled porcine experiments exploring blast injury and haemorrhagic shock. The effect of different CPAP levels was simulated in three in silico patients who had sustained mild, moderate, or severe PBLI (10%, 25%, 50% contusion of the total lung) plus haemorrhagic shock. The primary outcome was arterial partial pressure of oxygen (Pao2) at the end of each simulation. RESULTS: In mild blast lung injury, 5 cm H2O ambient-air CPAP increased Pao2 from 10.6 to 12.6 kPa. Higher CPAP did not further improve Pao2. In moderate blast lung injury, 10 cm H2O CPAP produced a larger increase in Pao2 (from 8.5 to 11.1 kPa), but 15 cm H2O CPAP produced no further benefit. In severe blast lung injury, 5 cm H2O CPAP inceased Pao2 from 4.06 to 8.39 kPa. Further increasing CPAP to 10-15 cm H2O reduced Pao2 (7.99 and 7.90 kPa, respectively) as a result of haemodynamic impairment resulting from increased intrathoracic pressures. CONCLUSIONS: Our modelling study suggests that ambient air 5 cm H2O CPAP may benefit casualties suffering from blast lung injury, even with severe haemorrhagic shock. However, higher CPAP levels beyond 10 cm H2O after severe lung injury reduced oxygen delivery as a result of haemodynamic impairment.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Mistry S, Das A, Hardman JG, et al. Pre-hospital continuous positive airway pressure after blast lung injury and hypovolaemic shock: a modelling study. Br J Anaesth. 2021. PMID: 34863511. doi:10.1016/j.bja.2021.10.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。