文献速递气道管理神经外科与老年麻醉

气管插管生物力学:完整颈椎下椎间运动与脊髓应变的计算建模临床意义

Intubation Biomechanics: Clinical Implications of Computational Modeling of Intervertebral Motion and Spinal Cord Strain during Tracheal Intubation in an Intact Cervical Spine.
PubMed 文献 · Anesthesiology · 2021-01-01

该计算建模研究基于完整颈椎模型,模拟48种插管力度条件(4个施力位置×4个力度×3个方向),预测椎间运动与脊髓应变。结果显示最大椎间运动未超过生理正常最大值,但3种非常规高力度条件下压缩应变超过潜在损伤阈值。对于脊髓急性应变耐受性低于正常的患者,常规力度下的压缩应变也可能达到潜在损伤值。

要点

  • 完整颈椎下,即使2倍常规插管力度,椎间运动未超生理正常最大值。
  • 48种力度条件中,3种非常规位置高力度条件下压缩应变超潜在损伤阈值。
  • 脊髓应变耐受性低于正常的患者,常规插管力度下压缩应变也可能有害。

核心结论

  • 完整颈椎下气管插管时椎间运动不超过生理正常最大值,但非常规高力度条件可产生潜在损伤性压缩应变。
  • 脊髓对急性应变耐受性低于正常的患者,常规插管力度下的压缩应变也可能达到潜在损伤值。

研究设计与样本

  • 研究利用颈椎与脊髓计算模型预测椎间运动(旋转、平移)和脊髓应变(拉伸、压缩)。
  • 常规(Macintosh)插管力度条件定义为特定施力位置(C3椎体中部)、力度48.8 N、方向70度。
  • 共模拟48种插管条件:4个施力位置(常规位置的头侧与尾侧)、4个力度(常规的50%至200%)、3个方向(50、70、90度)的所有组合。
  • 模型预测的最大椎间运动与既往临床研究中自主颈椎运动范围报告值比较,峰值脊髓应变与潜在应变损伤阈值比较。

主要发现

  • 模型预测的最大椎间运动出现在最大力度(97.6 N)条件下,与生理正常最大运动值无差异。
  • 48种力度条件中,峰值拉伸脊髓应变均未超过潜在损伤阈值(0.14)。
  • 48种条件中有3种峰值压缩应变超过潜在损伤阈值(-0.20),均为最大力度施加于非常规位置。

关键数值与推荐

  • 常规插管力度条件:施力位置为C3椎体中部,力度48.8 N,方向70度。
  • 模拟力度范围为常规的50%至200%,最大力度为97.6 N。
  • 潜在拉伸损伤阈值为0.14,潜在压缩损伤阈值为-0.20。

临床怎么用

  • 在颈椎完整(稳定)的患者中,常规插管力度下椎间运动不超过生理正常范围。
  • 应避免在非常规位置施加高力度插管,以降低潜在损伤性压缩应变风险。
  • 对脊髓急性应变耐受性低于正常的患者,即使常规插管力度也需警惕压缩应变可能达到损伤值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In a closed claims study, most patients experiencing cervical spinal cord injury had stable cervical spines. This raises two questions. First, in the presence of an intact (stable) cervical spine, are there tracheal intubation conditions in which cervical intervertebral motions exceed physiologically normal maximum values? Second, with an intact spine, are there tracheal intubation conditions in which potentially injurious cervical cord strains can occur? METHODS: This study utilized a computational model of the cervical spine and cord to predict intervertebral motions (rotation, translation) and cord strains (stretch, compression). Routine (Macintosh) intubation force conditions were defined by a specific application location (mid-C3 vertebral body), magnitude (48.8 N), and direction (70 degrees). A total of 48 intubation conditions were modeled: all combinations of 4 force locations (cephalad and caudad of routine), 4 magnitudes (50 to 200% of routine), and 3 directions (50, 70, and 90 degrees). Modeled maximum intervertebral motions were compared to motions reported in previous clinical studies of the range of voluntary cervical motion. Modeled peak cord strains were compared to potential strain injury thresholds. RESULTS: Modeled maximum intervertebral motions occurred with maximum force magnitude (97.6 N) and did not differ from physiologically normal maximum motion values. Peak tensile cord strains (stretch) did not exceed the potential injury threshold (0.14) in any of the 48 force conditions. Peak compressive strains exceeded the potential injury threshold (-0.20) in 3 of 48 conditions, all with maximum force magnitude applied in a nonroutine location. CONCLUSIONS: With an intact cervical spine, even with application of twice the routine value of force magnitude, intervertebral motions during intubation did not exceed physiologically normal maximum values. However, under nonroutine high-force conditions, compressive strains exceeded potentially injurious values. In patients whose cords have less than normal tolerance to acute strain, compressive strains occurring with routine intubation forces may reach potentially injurious values.

来源:Anesthesiology,查看原文。版权归原作者所有。

引用

  1. Gadomski BC, Hindman BJ, Page MI, et al. Intubation Biomechanics: Clinical Implications of Computational Modeling of Intervertebral Motion and Spinal Cord Strain during Tracheal Intubation in an Intact Cervical Spine. Anesthesiology. 2021. PMID: 34731240. doi:10.1097/ALN.0000000000004024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。