文献速递甲状腺疾病

粗钙化对非高可疑甲状腺结节A TA超声模式恶性风险的影响

Macrocalcifications Do Not Alter Malignancy Risk Within the American Thyroid Association Sonographic Pattern System When Present in Non-High Suspicion Thyroid Nodules.
PubMed 文献 · Thyroid · 2021-09-09

该回顾性研究纳入728个连续活检的甲状腺结节,评估非高可疑钙化(NHSC)结节按其他灰度特征归入ATA超声模式系统后的恶性风险。结果显示,NHSC中91%为粗钙化,其细胞学分布与可分类结节相似,未改变基于灰度特征的预期恶性风险;但伴点状强回声的LS结节癌患病率为19%。

要点

  • 粗钙化是NHSC的主要类型,不改变ATA超声模式系统基于灰度特征的恶性风险预期。
  • NHSC结节可按其他灰度特征归入ATA模式,其细胞学分布与可分类结节相似。
  • 伴点状强回声的LS结节癌患病率19%,需警惕但差异未达统计学显著。

核心结论

  • 粗钙化占NHSC的大多数,且不改变基于灰度特征的ATA超声模式系统预期恶性风险。

研究设计与样本

  • 回顾性 review 728个连续活检的甲状腺结节,按ATA超声模式系统分类,若因NHSC不可分类则仅根据灰度特征重新分配ATA模式。

主要发现

  • 144/728(20%)结节为不可分类模式,其中101/144(70%)有NHSC,归入IS(n=18)、LS(n=62)、VLS(n=21)。
  • NHSC组细胞学诊断分布与可分类结节相似(IS p=0.13,LS p=0.55,VLS p=0.44)。
  • 92/101(91%)NHSC为粗钙化(大的中心或线性营养不良性钙化);9个LS模式结节有点状强回声,估计癌患病率19%(vs 总LS组10%,p=0.24)。
  • 其余43/144(30%)不可分类结节包括实性不均匀回声(n=30)或完整环状边缘钙化(n=13),恶性11/43(26%)[9/30(30%)不均匀实性,2/13(15%)完整环状钙化]。

临床怎么用

  • 对于非高可疑结节伴粗钙化,可按其他灰度特征归入ATA模式评估恶性风险。
  • LS模式结节若有点状强回声,即使可能为微钙化,癌风险估计为19%,需结合其他特征综合判断。
  • 完整环状钙化或实性不均匀回声导致不可分类的结节恶性风险较高(分别为15%和30%),应谨慎管理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background: The American Thyroid Association Sonographic Pattern System (ATASPS) depicts five levels of suspicion for malignancy based on the sonographic appearance of a thyroid nodule. However, 3-37% of nodules are non-classifiable when the combination of grayscale findings is not depicted by the ATASPS. The only calcifications included in the ATASPS are in solid hypoechoic high suspicion (HS) nodules and include both microcalcifications and peripheral interrupted calcifications with soft tissue extrusion. Non-hypoechoic nodules with these and other calcification patterns, which we defined as non-high suspicion calcifications (NHSC), are not classifiable by ATASPS. We assessed the effect of assigning an ATASPS risk level to nodules with NHSC based on analysis of their other grayscale features. Methods: A retrospective review of 728 consecutively biopsied nodules was performed. Nodules were classified by ATASPS as HS, intermediate suspicion (IS), low suspicion (LS), or very low suspicion (VLS); other nodules with patterns not described by ATASPS were non-classifiable (NC). If NC was due to NHSC, the nodule was assigned an ATASPS by analysis of grayscale features alone. Cytology and pathology results were correlated with assigned ATASPS level. Results: A NC pattern was observed in 144 of the 728 nodules (20%). Of these, 101/144 (70%) had NHSC and the assigned ATASPS was IS (n = 18), LS (n = 62) and VLS (n = 21). The distribution of cytology diagnoses within this group was similar to classifiable nodules (IS p = 0.13, LS p = 0.55, VLS p = 0.44). The majority of NHSC (n = 92, 91%) were macrocalcifications (large central or linear dystrophic calcifications); however, 9 LS pattern nodules had punctate echogenic foci, possibly representing microcalcifcations, with an estimated cancer prevalence of 19% (vs. 10% for total LS group, p = 0.24). The remaining NC nodules (43/144, 30%) included solid nodules with heterogeneous echogenicity (n = 30) or presence of a complete circumferential rim calcification, limiting further sonographic assessment (n = 13). Malignancy was identified in 11 out of 43 (26%) of these [9/30 (30%) heterogeneous solid and 2/13 (15%) with complete rim calcifications]. Conclusions: Macrocalcifications accounted for the majority of NHSC and these did not alter the expected ATASPS malignancy risk based on grayscale features.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Kobaly K, Kim CS, Langer JE, et al. Macrocalcifications Do Not Alter Malignancy Risk Within the American Thyroid Association Sonographic Pattern System When Present in Non-High Suspicion Thyroid Nodules. Thyroid. 2021. PMID: 34314256. doi:10.1089/thy.2021.0140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。