规范采集的血浆甲氧基肾上腺素可排除假阳性筛查后的PPGL
本研究为回顾性队列研究,纳入无PPGL的门诊患者,比较尿液与坐位血浆甲氧基肾上腺素的关联,并评估规范准备和仰卧位采血的血浆甲氧基肾上腺素的假阳性率。结果显示尿液与坐位血浆甲氧基肾上腺素相关性差至中等,坐位血浆假阳性率可达20%,而规范仰卧位采血假阳性率低于3%。
要点
- 尿液与坐位血浆甲氧基肾上腺素相关性差至中等(r=0.33和0.50)。
- 无PPGL者中,尿液升高者约20%坐位血浆也升高。
- 规范准备仰卧位血浆甲氧基肾上腺素假阳性率<3%。
核心结论
- 尿液与坐位血浆甲氧基肾上腺素相关性差至中等,无PPGL时坐位血浆假阳性率可达20%。
- 规范准备和仰卧位采血的血浆甲氧基肾上腺素在无已知PPGL/肾上腺肿块者中假阳性率<3%。
研究设计与样本
- 回顾性队列研究,数据来自单中心省实验室(2012-2018)、PPGL登记库和内分泌检测单位病历审查。
- 纳入90天内同时有尿和血浆甲氧基肾上腺素的非PPGL门诊患者,实验室数据库共810对。
- 内分泌单位规范仰卧位采血患者139例(51%既往尿甲氧基肾上腺素高)。
主要发现
- 实验室数据库中46.1%的尿甲氧基肾上腺素报告为高。
- 坐位门诊血浆甲氧基肾上腺素(中位5.9天后采集)19.2%也高,去甲变肾上腺素和变肾上腺素相关系数分别为r=0.33和0.50。
- 规范仰卧位采血患者中,无已知PPGL/肾上腺肿块者异常高结果率<3%。
临床怎么用
- 对于尿甲氧基肾上腺素假阳性者,推荐规范准备后仰卧位采血复查血浆甲氧基肾上腺素以排除PPGL。
局限性
- 回顾性研究设计。
- 单中心数据。
- 未报告具体年龄调整参考范围细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT: False-positive results are common for pheochromocytoma/paraganglioma (PPGL) real-world screening. OBJECTIVE: Determine the correlation between screening urine and seated plasma metanephrines in outpatients where PPGL was absent, compared to meticulously prepared and supine-collected plasma metanephrines with age-adjusted references. DESIGN: Retrospective cohort study. SETTING: Databases from a single-provider provincial laboratory (2012-2018), a validated PPGL registry, and a manual chart review from a specialized endocrine testing unit. PATIENTS: PPGL registry data excluded known PPGL cases from the laboratory database. Outpatients having both urine and plasma metanephrines <90 days apart. METHODS: The correlation between urine and seated plasma measures along with the total positivity rate. All cases of plasma metanephrines drawn in the endocrine unit were reviewed for test indication and test positivity rate. RESULTS: There were 810 non-PPGL pairs of urine and plasma metanephrines in the laboratory database; 46.1% of urine metanephrines were reported high. Of seated outpatient plasma metanephrines drawn a median of 5.9 days later, 19.2% were also high (r = 0.33 and 0.50 for normetanephrine and metanephrine, respectively). In contrast, the meticulously prepared and supine collected patients (n = 139, 51% prior high urine metanephrines) had <3% rate of abnormal high results in patients without known PPGL/adrenal mass. CONCLUSIONS: There was a poor-to-moderate correlation between urine and seated plasma metanephrines. Up to 20% of those with high urine measures also had high seated plasma metanephrines in the absence of PPGL. Properly prepared and collected supine plasma metanephrines had a false-positive rate of <3% in the absence of known PPGL/adrenal mass.
引用
- Kline GA, Boyd J, Polzin B, et al. Properly Collected Plasma Metanephrines Excludes PPGL After False-Positive Screening Tests. J Clin Endocrinol Metab. 2021. PMID: 33846745. doi:10.1210/clinem/dgab241
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。