口服葡萄糖耐量试验1小时血糖诊断成人2型糖尿病的准确性:一项Meta分析
该Meta分析纳入15项研究、35551名参与者,以OGTT 2小时血糖≥11.1 mmol/L为金标准,评估1小时血糖诊断2型糖尿病的最佳切点。结果显示1小时血糖≥11.6 mmol/L时灵敏度0.92、特异度0.91,曲线下面积0.939,阳性预测值45%。建议先用糖尿病风险计算器筛查高危人群以减少假阳性。
要点
- OGTT 1小时血糖≥11.6 mmol/L诊断2型糖尿病灵敏度0.92、特异度0.91。
- 1小时血糖切点11.6 mmol/L的阳性预测值为45%。
- 建议先用糖尿病特异性风险计算器筛查高危个体以减少假阳性。
核心结论
- OGTT期间1小时血糖≥11.6 mmol/L对检出2型糖尿病具有良好灵敏度和特异度。
研究设计与样本
- Meta分析纳入15项研究、35551名参与者(53.8%为白种人)及2705例经OGTT 2小时血糖新检出的糖尿病病例。
主要发现
- 1小时血糖10.6、11.6、12.5 mmol/L切点在权重2/3、1/2、1/3时灵敏度分别为0.95、0.92、0.87,特异度分别为0.86、0.91、0.94。
- 切点11.6 mmol/L(95%CI 10.6, 12.6)灵敏度0.92(0.87, 0.95),特异度0.91(0.88, 0.93),曲线下面积0.939(给定特异度下灵敏度的95%置信区域:0.904, 0.946),阳性预测值45%。
关键数值与推荐
- 以OGTT 2小时血糖≥11.1 mmol/L作为糖尿病诊断金标准。
- 排除仅由空腹血糖升高和/或HbA1c识别的病例。
临床怎么用
- 可用OGTT 1小时血糖≥11.6 mmol/L辅助检出2型糖尿病。
- 建议先用糖尿病特异性风险计算器识别高危个体再行检测,以降低假阳性比例。
局限性
- 需纳入其他种族人群并评估并发症风险的研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: One-hour plasma glucose (1-h PG) during the oral glucose tolerance test (OGTT) is an accurate predictor of type 2 diabetes. We performed a meta-analysis to determine the optimum cutoff of 1-h PG for detection of type 2 diabetes using 2-h PG as the gold standard. RESEARCH DESIGN AND METHODS: We included 15 studies with 35,551 participants from multiple ethnic groups (53.8% Caucasian) and 2,705 newly detected cases of diabetes based on 2-h PG during OGTT. We excluded cases identified only by elevated fasting plasma glucose and/or HbA1c. We determined the optimal 1-h PG threshold and its accuracy at this cutoff for detection of diabetes (2-h PG ≥11.1 mmol/L) using a mixed linear effects regression model with different weights to sensitivity/specificity (2/3, 1/2, and 1/3). RESULTS: Three cutoffs of 1-h PG, at 10.6 mmol/L, 11.6 mmol/L, and 12.5 mmol/L, had sensitivities of 0.95, 0.92, and 0.87 and specificities of 0.86, 0.91, and 0.94 at weights 2/3, 1/2, and 1/3, respectively. The cutoff of 11.6 mmol/L (95% CI 10.6, 12.6) had a sensitivity of 0.92 (0.87, 0.95), specificity of 0.91 (0.88, 0.93), area under the curve 0.939 (95% confidence region for sensitivity at a given specificity: 0.904, 0.946), and a positive predictive value of 45%. CONCLUSIONS: The 1-h PG of ≥11.6 mmol/L during OGTT has a good sensitivity and specificity for detecting type 2 diabetes. Prescreening with a diabetes-specific risk calculator to identify high-risk individuals is suggested to decrease the proportion of false-positive cases. Studies including other ethnic groups and assessing complication risk are warranted.
引用
- Ahuja V, Aronen P, Pramodkumar TA, et al. Accuracy of 1-Hour Plasma Glucose During the Oral Glucose Tolerance Test in Diagnosis of Type 2 Diabetes in Adults: A Meta-analysis. Diabetes Care. 2021. PMID: 33741697. doi:10.2337/dc20-1688
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。