文献速递糖尿病

高胰岛素-低血糖葡萄糖钳夹技术:文献系统综述

Hyperinsulinaemic-hypoglycaemic glucose clamps in human research: a systematic review of the literature.
PubMed 文献 · Diabetologia · 2021-02-10

本系统综述检索PubMed和EMBASE,纳入1980至2018年发表的383篇成人高胰岛素-低血糖钳夹研究。研究发现钳夹方法学差异显著,包括胰岛素剂量相差49倍、低血糖步骤1-6个、最低血糖2.0-4.3 mmol/l、持续时间5-660分钟。61.9%的文章缺失关键信息,提示缺乏统一操作标准,比较不同研究结果时需考虑方法学差异。

要点

  • 低血糖钳夹研究的方法学存在显著异质性,胰岛素剂量相差达49倍。
  • 低血糖步骤数、最低血糖水平和持续时间范围宽泛,缺乏统一标准。
  • 61.9%的文章缺失关键方法学信息,影响结果可比性。

核心结论

  • 高胰岛素-低血糖钳夹被视为研究实验性低血糖的金标准,但缺乏统一的操作标准。
  • 比较不同低血糖钳夹研究结果时,应考虑方法学差异。

研究设计与样本

  • 系统综述,检索PubMed和EMBASE,纳入1980至2018年发表的英文文章。
  • 纳入对象为成人,伴或不伴糖尿病,共纳入383篇文章。

主要发现

  • 胰岛素剂量最低与最高率之间相差49倍。
  • 低血糖步骤数量范围为1至6个。
  • 低血糖最低值范围为2.0至4.3 mmol/l。
  • 钳夹持续时间范围为5至660分钟。

临床怎么用

  • 临床解读低血糖钳夹研究结果时,需注意各研究间方法学差异,不可直接横向比较。

局限性

  • 仅纳入英文发表文章,可能遗漏非英语研究。
  • 未报告纳入研究的偏倚风险评估细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS/HYPOTHESIS: The hyperinsulinaemic-hypoglycaemic glucose clamp technique has been developed and applied to assess effects of and responses to hypoglycaemia under standardised conditions. However, the degree to which the methodology of clamp studies is standardised is unclear. This systematic review examines how hyperinsulinaemic-hypoglycaemic clamps have been performed and elucidates potential important differences. METHODS: A literature search in PubMed and EMBASE was conducted. Articles in English published between 1980 and 2018, involving adults with or without diabetes, were included. RESULTS: A total of 383 articles were included. There was considerable variation in essential methodology of the hypoglycaemic clamp procedures, including the insulin dose used (49-fold difference between the lowest and the highest rate), the number of hypoglycaemic steps (range 1-6), the hypoglycaemic nadirs (range 2.0-4.3 mmol/l) and the duration (ranging from 5 to 660 min). Twenty-seven per cent of the articles reported whole blood glucose levels, most venous levels. In 70.8% of the studies, a dorsal hand vein was used for blood sampling, with some form of hand warming to arterialise venous blood in 78.8% of these. Key information was missing in 61.9% of the articles. CONCLUSIONS/INTERPRETATION: Although the hyperinsulinaemic-hypoglycaemic clamp procedure is considered the gold standard to study experimental hypoglycaemia, a uniform standard with key elements on how to perform these experiments is lacking. Methodological differences should be considered when comparing results between hypoglycaemic clamp studies. PROSPERO REGISTRATION: This systematic review is registered in PROSPERO (CRD42019120083).

来源:Diabetologia,查看原文。版权归原作者所有。

引用

  1. Fabricius TW, Verhulst CEM, Kristensen PL, et al. Hyperinsulinaemic-hypoglycaemic glucose clamps in human research: a systematic review of the literature. Diabetologia. 2021. PMID: 33566134. doi:10.1007/s00125-020-05361-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。