文献速递甲状腺疾病

甲状腺微小乳头状癌超声测量直径与体积的观察者间可重复性

Interobserver Reproducibility in Sonographic Measurement of Diameter and Volume of Papillary Thyroid Microcarcinoma.
PubMed 文献 · Thyroid · 2021-01-18

本研究回顾性纳入188例患者共197个经病理证实的甲状腺微小乳头状癌结节,由两名观察者独立采用标准化方法测量最大径与体积。结果显示体积和最大径的观察者间百分比可重复性系数分别为71.8%和23.7%,提示超声测量最大径差异至多24%、体积差异至多72%可能属于测量误差。

要点

  • PTMC超声测量最大径的观察者间百分比RC为23.7%,体积为71.8%。
  • 最大径差异≤24%、体积差异≤72%可能落在测量误差范围内。
  • 微钙化、结节大小及腺体背景不均质对ICC无显著影响。

核心结论

  • PTMC超声测量中最大径约24%、体积约72%以内的差异可视为测量误差。
  • 该数值可用于主动监测中定义最大径和体积有意义变化的切点。

研究设计与样本

  • 共188例患者197个甲状腺结节,两名观察者独立标准化测量最大径与体积。
  • 体积采用椭球公式计算,以百分比可重复性系数(RC)评估观察者间可重复性。

主要发现

  • 体积的观察者间百分比RC为71.8%(95%CI 65.4-79.7%)。
  • 最大径的观察者间百分比RC为23.7%(95%CI 21.6-26.3%)。
  • 按结节方向、钙化有无、大小或腺体不均质分组的ICC值无显著差异。

关键数值与推荐

  • 体积测量观察者间百分比RC为71.8%(95%CI 65.4-79.7%)。
  • 最大径测量观察者间百分比RC为23.7%(95%CI 21.6-26.3%)。

临床怎么用

  • 主动监测中评估PTMC最大径变化时,差异未超过约24%不宜判为有意义变化。
  • 评估体积变化时,差异未超过约72%不宜判为有意义变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background: Active surveillance is recommended as an alternative to immediate surgery for low-risk papillary thyroid microcarcinoma (PTMC), and determining meaningful changes in diameter and volume on ultrasonography (US) is critical. However, interobserver reproducibility of the sonographic measurement of maximum diameter and volume of PTMC has not been well established. We aimed to determine the reproducibility in the measurement of maximum diameter and volume of PTMC on US. Methods: Consecutive patients who underwent US for pathologically proven PTMC between December 2018 and December 2019 were retrospectively reviewed. Two observers independently performed sonographic measurement of each nodule using standardized measurement methods. Each observer measured maximum transverse, anteroposterior, and longitudinal nodule diameters, and using these, nodule volume was calculated using the ellipsoid formula. Interobserver reproducibility in the measurement of the maximum diameter and volume was assessed using percentage reproducibility coefficient (RC). Z-tests of the intraclass correlation coefficients (ICCs) were used to compare the interobserver reproducibility in subgroups defined according to sonographic characteristics, such as the presence of microcalcification, nodule size, and parenchymal heterogeneity. Results: A total of 197 thyroid nodules from 188 patients were included in the study series. The percentage RCs were 71.8% [95% confidence interval, CI 65.4-79.7%] and 23.7% [CI 21.6-26.3%] for volume and maximum diameter measurements, respectively. There were no significant differences noted in the ICC values according to nodule orientation, presence of calcifications, size, or parenchymal heterogeneity. Conclusion: For PTMC, a difference of up to 24% in the maximum diameter and 72% in the volume may be considered to be within measurement error on US. This value may be used to determine the cutoff for defining meaningful change in the maximum diameter and volume for PTMC during active surveillance.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Chung SR, Choi YJ, Lee SS, et al. Interobserver Reproducibility in Sonographic Measurement of Diameter and Volume of Papillary Thyroid Microcarcinoma. Thyroid. 2021. PMID: 33287640. doi:10.1089/thy.2020.0317

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。