文献速递糖尿病

四种基于肌酐的公式在糖尿病患者肾小球滤过率评估中的表现

Performance of 4 Creatinine-based Equations in Assessing Glomerular Filtration Rate in Adults with Diabetes.
PubMed 文献 · J Clin Endocrinol Metab · 2021-01-01

这项横断面研究纳入1487例糖尿病患者(共2703次测量),以99mTc-DTPA测定的mGFR为参考,比较MDRD、CKD-EPI、FAS和r-LM四种eGFR公式的诊断性能。结果显示r-LM的CCC最高(0.83)、偏倚最低(-1.4 mL/min/1.73m2)、精确度最高(16.2 mL/min/1.73m2)、准确度最高(P10=39%)。结论认为在成人糖尿病患者中,r-LM在计算GFR点估计值方面优于其他三种公式。

要点

  • r-LM公式在糖尿病患者中CCC最高、偏倚最低。
  • r-LM的P10为39%,准确度优于MDRD、CKD-EPI和FAS。
  • r-LM的95%一致性界限最窄(-1.0至54.1 mL/min/1.73m2)。

核心结论

  • 在成人糖尿病患者中,r-LM公式计算GFR点估计值的性能优于MDRD、CKD-EPI和FAS。

研究设计与样本

  • 横断面研究,纳入至少1次99mTc-DTPA mGFR和血清肌酐测量的患者,共1487例患者、2703次测量。

主要发现

  • r-LM的CCC最高(0.83),偏倚最低(-1.4 mL/min/1.73m2),精确度最高(16.2 mL/min/1.73m2),准确度最高(P10=39%)。
  • r-LM、FAS、MDRD和CKD-EPI的RMAR斜率与截距分别为1.18、-13.35;0.97、-2.9;1、-6.4;1.04、-11.3。
  • Bland-Altman分析显示r-LM平均差异最低(-1.0 mL/min/1.73m2),95%一致性界限最窄(-1.0至54.1 mL/min/1.73m2)。
  • FAS、MDRD和CKD-EPI的平均差异分别为-5.2、-6.3和-8.2 mL/min/1.73m2,均超过r-LM的5倍以上。

临床怎么用

  • 在评估成人糖尿病患者GFR时,可优先考虑使用r-LM公式以提高点估计值的准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To evaluate diagnostic performance of glomerular filtration rate (GFR) estimated by modification of diet in renal disease (MDRD), chronic kidney disease epidemiology collaboration (CKD-EPI), full age spectrum (FAS), and revised Lund-Malmö (r-LM) equations in adults with diabetes. METHODS: Individuals were included in this cross-sectional study if they had at least 1 measurement of technetium-99m diethylenetriamine-pentaacetic acid (99mTc-DTPA) GFR (mGFR) and serum creatinine (1487 patients with 2703 measures). GFR calculated by estimation equations was compared with mGFR. Diagnostic performance was assessed using concordance correlation coefficient (CCC), bias, precision, accuracy, reduced major axis regression (RMAR), and Bland-Altman plot. Analysis was repeated in subgroups based on sex, diabetes type, Hemoglobin A1C, and GFR level. RESULTS: Of all patients, 1189 (86%) had type 2 diabetes. Mean mGFR, MDRD, CKD-EPI, FAS, and revised Lund-Malmö eGFR were 66, 72, 74, 71, and 67 mL/min/1.73m2, respectively. Overall, the r-LM had the highest CCC (0.83), lowest bias (-1.4 mL/min/1.73 m2), highest precision (16.2 mL/min/1.73 m2), and highest accuracy (P10 = 39%). The RMAR (slope, intercept) in r-LM, FAS, MDRD, and CKD-EPI was 1.18, -13.35; 0.97, -2.9; 1, -6.4, and 1.04, -11.3, respectively. The Bland-Altman plot showed that r-LM had the lowest mean difference and the narrowest 95% limit of agreement (-1.0, 54.1 mL/min/1.73 m2), while mean difference was more than 5-fold higher in FAS, MDRD, and CKD-EPI (-5.2, -6.3, and -8.2, respectively). CONCLUSIONS: In adults with diabetes the revised Lund-Malmö performs better than MDRD, CKD-EPI, and FAS in calculating point estimates of GFR.

来源:J Clin Endocrinol Metab,查看原文。版权归原作者所有。

引用

  1. Zafari N, Lotfaliany M, O'Keefe GJ, et al. Performance of 4 Creatinine-based Equations in Assessing Glomerular Filtration Rate in Adults with Diabetes. J Clin Endocrinol Metab. 2021. PMID: 33090207. doi:10.1210/clinem/dgaa722

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。