文献速递糖尿病

实时持续葡萄糖监测在1型糖尿病血糖控制中优于扫描式葡萄糖监测:CORRIDA随机对照试验

Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial.
PubMed 文献 · Diabetes Care · 2020-08-28

CORRIDA随机对照试验纳入60例低血糖感知正常的1型糖尿病成人,比较实时持续葡萄糖监测(rtCGM)与间歇扫描式持续葡萄糖监测(isCGM)在4天运动期及随后4周居家期的疗效。rtCGM组低血糖时间占比在运动期和居家期均低于isCGM组,葡萄糖目标范围内时间占比均高于isCGM组。结论认为rtCGM在减少低血糖和改善目标范围内时间方面优于isCGM,体现rtCGM警报在运动和日常自我管理中的价值。

要点

  • 运动期低血糖时间占比rtCGM组6.8±5.5% vs isCGM组11.4±8.6%(P=0.018)。
  • 居家期低血糖时间占比rtCGM组5.3±2.5% vs isCGM组7.3±4.4%(P=0.035)。
  • 运动期目标范围内时间占比rtCGM组78.5±10.2% vs isCGM组69.7±16%(P=0.0149)。

核心结论

  • 在低血糖感知正常的1型糖尿病成人中,rtCGM在减少低血糖和改善目标范围内时间方面优于isCGM,体现rtCGM警报在运动和日常糖尿病自我管理中的价值。

研究设计与样本

  • 随机对照试验纳入60例低血糖感知正常(Gold评分<4)的1型糖尿病成人,随机分为rtCGM组(n=30,Guardian Connect Mobile)和isCGM组(n=30,FreeStyle Libre)。
  • 受试者在4天运动期及随后4周居家期使用相应设备,isCGM组额外佩戴盲化Enlite传感器(iPro2)6天以检查传感器间偏倚。
  • 主要终点为低血糖时间占比(<3.9 mmol/L [<70 mg/dL])和目标范围内时间占比(3.9-10.0 mmol/L [70-180 mg/dL])。

主要发现

  • 运动期低血糖时间占比rtCGM组6.8±5.5% vs isCGM组11.4±8.6%(P=0.018),居家期rtCGM组5.3±2.5% vs isCGM组7.3±4.4%(P=0.035)。
  • 低血糖差异显著且夜间最为明显。
  • 运动期目标范围内时间占比rtCGM组78.5±10.2% vs isCGM组69.7±16%(P=0.0149),居家期rtCGM组75.6±9.7% vs isCGM组67.4±17.8%(P=0.0339)。
  • 结果对rtCGM与isCGM传感器间盲化CGM发现的非显著偏倚稳健。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this trial was to compare the efficacy of real-time and intermittently scanned continuous glucose monitoring (rtCGM and isCGM, respectively) in maintaining optimal glycemic control. RESEARCH DESIGN AND METHODS: In this randomized study, adults with type 1 diabetes (T1D) and normal hypoglycemia awareness (Gold score <4) used rtCGM (Guardian Connect Mobile) or isCGM (FreeStyle Libre) during 4 days of physical activity (exercise phase) and in the subsequent 4 weeks at home (home phase). Primary end points were time in hypoglycemia (<3.9 mmol/L [<70 mg/dL]) and time in range (3.9-10.0 mmol/L [70-180 mg/dL]). The isCGM group wore an additional masked Enlite sensor (iPro2) for 6 days to check for bias between the different sensors used by the rtCGM and isCGM systems. RESULTS: Sixty adults with T1D (mean age 38 ± 13 years; A1C 62 ± 12 mmol/mol [7.8 ± 1.1%]) were randomized to rtCGM (n = 30) or isCGM (n = 30). All participants completed the study. Percentage of time in hypoglycemia (<3.9 mmol/L [<70 mg/dL]) was lower among rtCGM versus isCGM participants in the exercise phase (6.8 ± 5.5% vs. 11.4 ± 8.6%, respectively; P = 0.018) and during the home phase (5.3 ± 2.5% vs. 7.3 ± 4.4%, respectively; P = 0.035). Hypoglycemia differences were significant and most notable during the night. rtCGM participants spent more time in range (3.9-10 mmol/L [70-180 mg/dL]) than isCGM participants throughout both the exercise (78.5 ± 10.2% vs. 69.7 ± 16%, respectively; P = 0.0149) and home (75.6 ± 9.7% vs. 67.4 ± 17.8%, respectively; P = 0.0339) phases. The results were robust to the insignificant bias between rtCGM and isCGM sensors that masked CGM found in the isCGM arm. CONCLUSIONS: rtCGM was superior to isCGM in reducing hypoglycemia and improving time in range in adults with T1D with normal hypoglycemia awareness, demonstrating the value of rtCGM alarms during exercise and in daily diabetes self-management.

来源:Diabetes Care,查看原文。版权归原作者所有。

引用

  1. Hásková A, Radovnická L, Petruželková L, et al. Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial. Diabetes Care. 2020. PMID: 32859607. doi:10.2337/dc20-0112

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。