坐位盐水抑制试验诊断原发性醛固酮增多症:免疫法与HPLC-MS/MS差异
本研究比较化学发光免疫法(PACIA)与HPLC-MS/MS在坐位盐水抑制试验(SSST)中诊断原发性醛固酮增多症(PA)的切点差异。80例受试者中65例确诊PA、15例排除,ROC分析显示4小时PACIA最佳切点为171 pmol/L,灵敏度95.4%、特异度80.0%。免疫法需采用高于HPLC-MS/MS的切点,171–217 pmol/L为灰区。
要点
- 免疫法测PAC时SSST诊断PA的切点应高于HPLC-MS/MS的162 pmol/L。
- 4小时PACIA<171 pmol/L可排除PA,>217 pmol/L高度提示PA。
- 171–217 pmol/L为灰区,可能反映免疫法特异度较低。
核心结论
- 免疫法测血浆醛固酮时SSST诊断PA的切点应高于HPLC-MS/MS的推荐切点162 pmol/L。
研究设计与样本
- 分析近期定义HPLC-MS/MS切点研究中87例SSST中的80例,65例经氟氢可的松抑制试验阳性和/或肾上腺静脉采血侧化确诊PA,15例经FST阴性排除。
- 用DiaSorin Liaison XL分析仪以化学发光免疫法(PACIA)测SSST样本醛固酮,行ROC分析确定PACIA切点。
主要发现
- 4小时PACIA诊断PA的ROC曲线下面积0.893(P<.001)。
- 最佳切点171 pmol/L,灵敏度95.4%、特异度80.0%;切点217 pmol/L时特异度86.7%、灵敏度86.2%。
- PACIA与HPLC-MS/MS测值强相关(r=0.94,P<.001)。
关键数值与推荐
- 4小时PACIA<171 pmol/L可排除PA。
- 化学发光免疫法4小时PACIA>217 pmol/L高度提示PA。
- 171–217 pmol/L为灰区,可能反映免疫法特异度较低。
临床怎么用
- 用免疫法测PAC时,SSST诊断PA应采用高于HPLC-MS/MS的切点。
- 4小时PACIA<171 pmol/L可排除PA,>217 pmol/L高度提示PA,171–217 pmol/L需进一步评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In primary aldosteronism (PA), excessive, autonomous secretion of aldosterone is not suppressed by salt loading or fludrocortisone. For seated saline suppression testing (SSST), the recommended diagnostic cutoff 4-hour plasma aldosterone concentration (PAC) measured by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS is 162 pmol/L. Most diagnostic laboratories, however, use immunoassays to measure PAC. The cutoff for SSST using immunoassay is not known. We hypothesized that the cutoff is different between the assays. METHODS: We analyzed 80 of the 87 SSST tests that were performed during our recent study defining the HPLC-MS/MS cutoff. PA was confirmed in 65 by positive fludrocortisone suppression testing (FST) and/or lateralization on adrenal venous sampling and excluded in 15 by negative FST. PAC was measured by a chemiluminescence immunoassay (PACIA) in the SSST samples using the DiaSorin Liaison XL analyzer, and receiver operating characteristics (ROC) analysis was performed to identify the PACIA cutoff. RESULTS: ROC revealed good performance (area under the curve = 0.893; P < .001) of 4-hour postsaline PACIA for diagnosis of PA and an optimal diagnostic cutoff of 171 pmol/L, with sensitivity and specificity of 95.4% and 80.0%, respectively. A higher cutoff of 217 pmol/L improved specificity (86.7%) with lower sensitivity (86.2%). PACIA measurements strongly correlated with PAC measured by HPLC-MS (r = 0.94, P < .001). CONCLUSIONS: A higher diagnostic cutoff for SSST should be employed when PAC is measured by immunoassay rather than HPLC-MS/MS. The results suggest that (i) PA can be excluded if 4-hour PACIA is less than 171 pmol/L, and (ii) PA is highly likely if the PACIA is greater than 217 pmol/L by chemiluminescence immunoassay. A gray zone exists between the cutoffs of 171 and 217 pmol/L, likely reflecting a lower specificity of immunoassay.
引用
- Thuzar M, Young K, Ahmed AH, et al. Diagnosis of Primary Aldosteronism by Seated Saline Suppression Test-Variability Between Immunoassay and HPLC-MS/MS. J Clin Endocrinol Metab. 2020. PMID: 31676899. doi:10.1210/clinem/dgz150
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。