肥胖且甲状旁腺功能正常者因人抗鼠抗体致PTH免疫测定干扰
一例36岁肥胖女性(BMI 31 kg/m2)作为肥胖管理研究对照接受详细实验室检查,在血钙、磷、维生素D均正常且无临床症状的情况下,Roche Elecsys电化学发光法测得的PTH>5000 ng/L,换用Euroimmun羊抗体法测得PTH为18.0 ng/L。经异嗜性抗体阻断剂预处理后Roche法结果降至正常,血清中检出人抗鼠抗体,提示为测定干扰所致。
要点
- PTH极度升高但血钙、磷、维生素D正常且无症状时,应警惕免疫测定干扰。
- 不同抗体平台的PTH结果差异悬殊时,可用异嗜性抗体阻断剂预处理或换用其他方法验证。
- 本例推测人抗鼠抗体在体外与测定抗体作用,人工放大Roche检测系统信号。
核心结论
- 肥胖且甲状旁腺功能正常者中,人抗鼠抗体可干扰PTH免疫测定,造成PTH假性极度升高。
研究设计与样本
- 单例病例报告:36岁肥胖女性(BMI 31 kg/m2),因2型糖尿病在内分泌科随访,作为肥胖管理研究的对照受试者接受含PTH的详细实验室检查。
主要发现
- 血钙、磷、维生素D水平正常且无临床症状,但Roche Elecsys电化学发光法(鼠抗体)测得PTH>5000 ng/L,重复测定结果相同。
- Euroimmun法(羊抗体)测得PTH为18.0 ng/L。
- 经异嗜性抗体阻断剂预处理后,Roche法结果降至正常水平。
- 血清中检出人抗鼠抗体,解释上述现象。
关键数值与推荐
- Roche Elecsys法(鼠抗体)PTH>5000 ng/L,重复测定结果一致。
- Euroimmun法(羊抗体)PTH为18.0 ng/L。
- 异嗜性抗体阻断剂预处理后Roche法结果降至正常水平。
临床怎么用
- PTH升高与血钙、磷、维生素D及临床表现不符时,应考虑免疫测定干扰并换用不同抗体平台复测。
- 疑诊异嗜性抗体干扰时,可用异嗜性抗体阻断剂预处理后复测。
- 解读PTH结果需结合检测平台抗体来源及临床背景。
局限性
- 仅为单例病例报告,结论外推需谨慎。
- 摘要未报告人抗鼠抗体的具体检测方法及滴度等信息。
- 未报告干扰对临床诊疗决策影响的随访数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT: Immunoassay interference has been most often found with prolactin measurement. However, only few data exist on immunoassay interference for other hormones. CASE DESCRIPTION: A 36-year-old woman with obesity (body mass index, 31 kg/m2) had regularly attended our endocrine unit for type 2 diabetes therapy. When she was included as a control subject in a study for obesity management, detailed laboratory testing was performed, including PTH. In the absence of clinical symptoms, she presented with normal calcium, phosphate, and vitamin D levels. However, the PTH levels were >5000 ng/L. These results were obtained using the Roche Elecsys electrochemiluminescence assay. Repeated measurements with this assay (mouse antibody) led to the same findings. However, using an Euroimmun assay (goat antibody), the exact PTH values were measured at 18.0 ng/L. After pretreatment with a heterophilic antibody blocking reagent, the results of the Roche assay had decreased to a normal level. This phenomenon was explained by the detection of human anti-mouse antibodies in the proband's serum. CONCLUSIONS: In cases of prolactin immunoassay interference, endogenous antibodies will bind to the hormone in vivo, resulting in complexes of a high molecular weight that are less efficiently cleared by the kidneys and, thus, accumulate in the blood. In contrast, the PTH values >5000 ng/L detected in our subject most likely had resulted from the specific interference of the human anti-mouse antibodies present in the proband's serum with the assay antibody, resulting in artificial stimulation of the Roche assay detection system ex vivo.
引用
- Laudes M, Frohnert J, Ivanova K, et al. PTH Immunoassay Interference Due to Human Anti-Mouse Antibodies in a Subject With Obesity With Normal Parathyroid Function. J Clin Endocrinol Metab. 2019. PMID: 31411693. doi:10.1210/jc.2019-01321
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。