ACTH兴奋下肾上腺静脉采血与无兴奋采血的Meta分析
该Meta分析纳入14项比较ACTH兴奋与否的肾上腺静脉采血(AVS)研究,发现ACTH兴奋未显著减少错误侧化(OR 0.76,95%CI 0.36–1.59,P=0.47),但显著减少双侧肾上腺静脉插管失败(OR 0.26,95%CI 0.17–0.40,P<0.00001),亚组分析亦减少左、右侧插管失败。
要点
- ACTH兴奋未显著降低错误侧化率(OR 0.76,P=0.47)。
- ACTH兴奋显著减少双侧肾上腺静脉插管失败(OR 0.26,P<0.00001)。
- 左、右侧插管失败率亦分别显著降低(OR 0.14和0.30)。
核心结论
- ACTH兴奋下AVS可显著减少插管失败,但未显著减少错误侧化。
研究设计与样本
- 检索Cochrane Library、PubMed、Embase和Web of Science数据库,纳入14项比较ACTH兴奋与无兴奋AVS的队列研究。
主要发现
- ACTH兴奋未显著减少错误侧化(OR 0.76,95%CI 0.36–1.59,P=0.47)。
- ACTH兴奋显著减少双侧肾上腺静脉插管失败(OR 0.26,95%CI 0.17–0.40,P<0.00001)。
- ACTH兴奋显著减少左侧肾上腺静脉插管失败(OR 0.14,95%CI 0.06–0.33,P<0.00001)。
- ACTH兴奋显著减少右侧肾上腺静脉插管失败(OR 0.30,95%CI 0.12–0.71,P=0.007)。
临床怎么用
- 在原发性醛固酮增多症患者行AVS时,可考虑使用ACTH兴奋以提高插管成功率。
局限性
- 需进一步研究验证这些发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT: Adrenal venous sampling (AVS) with or without adrenocorticotropic hormone (ACTH) stimulation is the test of choice to identify patients with a surgically curable subtype of primary aldosteronism (PA). Whether AVS with ACTH stimulation is more effective than AVS without ACTH stimulation remains controversial. OBJECTIVE: To compare the effectiveness of AVS with ACTH stimulation and AVS without ACTH stimulation in patients with PA. METHODS: The Cochrane Library, PubMed, Embase, and Web of Science databases were searched to identify relevant articles. All cohort studies comparing the 2 techniques (AVS with ACTH stimulation and AVS without ACTH stimulation in patient with PA) were included in the analysis. RESULTS: A total of 14 studies met the inclusion criteria, and they were analyzed. AVS with ACTH stimulation did not significantly reduce the number of incorrect lateralization more than AVS without ACTH stimulation in patients with PA [OR: 0.76, 95% confidence interval (CI): 0.36, 1.59; P=0.47]. AVS with ACTH stimulation significantly reduced the number of unsuccessful cannulations of both adrenal veins more than AVS without ACTH stimulation in patients with PA (OR: 0.26, 95% CI: 0.17, 0.40; P<0.00001). For subgroup analyses, it also significantly reduced the number of unsuccessful cannulations of left adrenal vein and right adrenal vein (OR: 0.14, 95% CI: 0.06, 0.33; P<0.00001 and OR: 0.30, 95% CI: 0.12, 0.71; P=0.007, respectively). CONCLUSION: AVS with ACTH stimulation can significantly reduce the number of unsuccessful cannulations, without significantly reducing the number of incorrect lateralization. Further studies are still needed to verify these findings.
引用
- Laurent I, Astère M, Zheng F, et al. Adrenal venous sampling with or without adrenocorticotropic hormone stimulation: A meta-analysis. J Clin Endocrinol Metab. 2018. PMID: 30403797. doi:10.1210/jc.2018-01324
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。