甲状腺结节穿刺应采用毛细管法及24-27G针头:系统综述与Meta分析
该系统综述与Meta分析纳入24篇文章共4428个结节,评估毛细管法对比抽吸法及针头口径对甲状腺细针穿刺活检诊断成功率的影响。结论建议常规甲状腺结节穿刺不抽吸并使用较小针头(24-27G)。
要点
- 毛细管法较抽吸法显著降低无诊断细胞学病理相对风险(RR=0.57)。
- 较小针头口径在减少无诊断结果方面呈非显著有利趋势。
- 推荐常规甲状腺结节穿刺采用不抽吸毛细管法及24-27G针头。
核心结论
- 毛细管法可显著降低无诊断细胞学病理率,较小针头口径呈非显著有利趋势。
- 鉴于毛细管法降低无诊断率且大针头可能增加疼痛和并发症而无证实获益,常规甲状腺结节穿刺应不抽吸并使用较小针头(24-27G)。
研究设计与样本
- 系统综述与Meta分析,检索Medline、Embase和Cochrane数据库,遵循PRISMA指南。
- 除两项研究外均为前瞻性研究,大多数为盲法试验伴或不伴随机化。
主要发现
- 较小针头口径在减少无诊断结果方面呈非显著有利趋势。
关键数值与推荐
- 推荐常规甲状腺结节穿刺不抽吸并使用较小针头口径(24-27G)。
临床怎么用
- 常规甲状腺结节细针穿刺活检应采用毛细管法(不抽吸)并使用24-27G针头。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fine-needle biopsy is the international standard for diagnostic evaluation of thyroid nodules. There is a lack of consensus regarding the optimal needle biopsy technique. The implementation of capillary action versus aspiration and the optimal needle gauge remain topics of debate. METHODS: A systematic review of the Medline, Embase, and Cochrane databases was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Articles evaluating the effects of capillary action versus aspiration and needle gauge on success rates of fine-needle biopsy of the thyroid were assessed for inclusion. The primary outcome of interest was the rate of non-diagnostic cytopathology. RESULTS: Twenty-four articles with a collective 4428 nodules were ultimately included in the review. Twenty articles evaluated capillary action versus aspiration, and six evaluated needle gauge. All but two studies were prospective, most of which were blinded trials with or without randomization. Using a random-effects model, capillary action was associated with a statistically significant reduction in the relative risk of non-diagnostic cytopathology (relative risk = 0.57 [confidence interval 0.34-0.92]; p = 0.02). There was a nonsignificant trend in favor of smaller needle gauges. CONCLUSION: Given the statistically significant deceased rate of non-diagnostic cytopathology with capillary action and the potential for increased pain and complications with larger needles without a proven benefit, needle biopsy of routine thyroid nodules should be performed without aspiration and with smaller needle gauges (24-27G).
引用
- Moss WJ, Finegersh A, Pang J, et al. Needle Biopsy of Routine Thyroid Nodules Should Be Performed Using a Capillary Action Technique with 24- to 27-Gauge Needles: A Systematic Review and Meta-Analysis. Thyroid. 2018. PMID: 29742978. doi:10.1089/thy.2017.0643
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。