该研究对96,942例连续行18F-FDG PET/CT患者中1342例甲状腺局灶性摄取者行超声评估,最终纳入877例907个结节进行回顾性分析。按ATA和K-TIRADS指南对超声图像分层,甲状腺偶发瘤总体恶性风险为54.7%,高度和中度可疑结节的恶性风险高于指南所示,低度和极低度可疑结节的恶性风险在指南范围内。结论认为超声可用于对PET/CT发现的甲状腺偶发瘤进行恶性风险分层,低度和极低度可疑者恶性风险未增加,可能仅需选择性活检。

要点

  • 18F-FDG PET/CT发现的甲状腺偶发瘤总体恶性风险为54.7%。
  • 超声高度可疑和中度可疑结节的恶性风险分别为93.2%和45.2%,高于指南所示。
  • 低度和极低度可疑结节的恶性风险分别为8.1%和0%,在指南范围内,可能仅需选择性活检。

核心结论

  • 超声检查可用于对18F-FDG PET/CT发现的甲状腺偶发瘤进行恶性风险分层。
  • 低度和极低度可疑甲状腺偶发瘤的恶性风险未增加,可能仅需选择性活检。

研究设计与样本

  • 1342例患者共1364个结节因甲状腺局灶性摄取行超声评估,最终对877例患者共907个结节作出最终诊断并纳入分析。
  • 超声图像回顾性审阅,按美国甲状腺协会(ATA)和韩国甲状腺影像报告和数据系统(K-TIRADS)指南进行分层。
  • 将计算得到的恶性风险与指南建议的估计风险进行比较。

主要发现

  • 18F-FDG PET/CT发现的甲状腺偶发瘤总体恶性风险为54.7%。
  • 按ATA指南分层,高度可疑和中度可疑甲状腺偶发瘤的恶性风险分别为93.2%和45.2%,高于指南所示。
  • 按ATA指南分层,低度和极低度可疑甲状腺偶发瘤的恶性风险分别为8.1%和0%,在指南范围内。
  • 按K-TIRADS分层及在>1 cm结节亚组中亦观察到上述结果。

关键数值与推荐

  • ATA指南分层:高度可疑结节恶性风险93.2%,中度可疑45.2%,低度可疑8.1%,极低度可疑0%。

临床怎么用

  • 对18F-FDG PET/CT发现的甲状腺偶发瘤行超声检查以进行恶性风险分层。
  • 低度和极低度可疑甲状腺偶发瘤可能仅需选择性活检。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aims of this study were to stratify the risk of malignancy in thyroid incidentalomas detected on 18F-fluorodeoxyglucose positron emission tomography with computed tomography (18F-FDG PET/CT) using ultrasound features according to guidelines for thyroid nodules and to develop a subsequent management plan. METHODS: From a historical cohort of 96,942 consecutive patients who underwent 18F-FDG PET/CT between October 2008 and September 2015, 1342 patients with 1364 nodules underwent ultrasound evaluation for focal uptake in thyroid gland, with a final diagnosis made for 877 patients with 907 nodules, which were included in this study. Ultrasound images were retrospectively reviewed, and they were stratified according to the American Thyroid Association and Korean Thyroid Image Reporting and Data System guidelines. The calculated malignancy risks were compared with the estimated risks suggested by the guidelines. RESULTS: The overall malignancy risk of thyroid incidentalomas detected on 18F-FDG PET/CT was 54.7%. When stratified according to the American Thyroid Association guidelines, the malignancy risks of thyroid incidentalomas with high and intermediate suspicion (93.2% and 45.2%, respectively) were higher than those indicated in the guidelines. The malignancy risks of thyroid incidentalomas with low and very low suspicion (8.1% and 0%, respectively) were within the guideline ranges. These findings were also noted when thyroid incidentalomas were stratified according to the Korean Thyroid Image Reporting and Data System, and in a subgroup of nodules >1 cm. CONCLUSIONS: Ultrasound examinations can be used to stratify the malignancy risk of thyroid incidentalomas detected on 18F-FDG PET/CT. The risk of malignancy did not increase in thyroid incidentalomas with low and very low suspicion, indicating that only selective biopsies may be needed in these categories of thyroid incidentalomas.