文献速递甲状腺疾病

剪切波弹性成像在细胞学不确定甲状腺结节中的应用:一项前瞻性双中心研究结果

Shear Wave Elastography in Thyroid Nodules with Indeterminate Cytology: Results of a Prospective Bicentric Study.
PubMed 文献 · Thyroid · 2017-01-01

这项前瞻性双中心研究纳入131例细胞学不确定(Bethesda III-V)且推荐手术的甲状腺结节患者,评估剪切波弹性成像(SWE)预测恶性、可重复性及与超声联合分析的价值。术后21个(16%)结节为恶性,良恶性结节间SWE参数(平均弹性、最大弹性、比值)相似;经典型乳头状甲状腺癌变异型的弹性值较高,但常规SWE指标未能区分良恶性。

要点

  • 在细胞学不确定的甲状腺结节中,良性与恶性结节的平均弹性、最大弹性和弹性比值均相似。
  • 经典型乳头状甲状腺癌变异型的平均弹性、最大弹性和比值高于其他乳头状癌变异型及非乳头状癌肿瘤。
  • 结节平均弹性的观察者内和观察者间变异系数分别为23%和26%。

核心结论

  • 尽管经典型乳头状甲状腺癌变异型弹性值较高,常规剪切波弹性成像指标未能区分细胞学不确定甲状腺结节的良恶性。

研究设计与样本

  • 前瞻性双中心研究,纳入131例甲状腺结节≥15 mm且细胞学不确定(Bethesda III-V类)、已推荐手术的患者,行标准化超声联合剪切波弹性成像检查后手术。

主要发现

  • 131个结节(中位大小30 mm)中,细胞学III类占28%、IV类占64%、V类占8%;术后21个(16%)为恶性。
  • 良性与恶性结节的平均弹性(20.2 vs. 19.6 kPa)、最大弹性(34.3 vs. 32.5 kPa)和比值(1.57 vs. 1.38)相似。
  • 恶性结节中,经典型乳头状甲状腺癌变异型(n=4)的平均弹性、最大弹性和比值高于其他乳头状癌变异型(n=5;p<0.02)和非乳头状癌肿瘤(n=12;p<0.005)。
  • 结节平均弹性的观察者内和观察者间变异系数分别为23%和26%。
  • 法国甲状腺影像报告和数据系统评分、美国甲状腺协会超声分类及EU-甲状腺影像报告和数据系统与恶性均不相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The clinical management of thyroid nodules with indeterminate cytology (IC) remains challenging. The role of shear wave elastography (SWE) in this setting is controversial. The aim of the study was to assess the performances of SWE in terms of prediction of malignancy, reproducibility, and combined analysis with ultrasound (US) examination in thyroid nodules with IC. METHODS: This prospective study was conducted in two referral centers. Eligible patients had a thyroid nodule ≥15 mm with IC (Bethesda class III-V) for which surgery had been recommended. Patients underwent a standardized US evaluation combined with a SWE exam followed by surgery. SWE parameters included mean (meanEI; kPa) and max (maxEI) elasticity values, and ratio (meanEI nodule/parenchyma). RESULTS: One hundred and thirty-one nodules (median size 30 mm) in 131 patients were studied. IC was class III in 28%, class IV in 64%, and class V in 8% of cases. After surgery, 21 (16%) nodules were malignant, including nine papillary thyroid cancers (PTC), six follicular thyroid cancers, five poorly differentiated carcinomas, and one large B-cell lymphoma. SWE parameters were similar in benign and malignant nodules, including meanEI (20.2 vs. 19.6 kPa), maxEI (34.3 vs. 32.5 kPa), and ratio (1.57 vs. 1.38). In malignant nodules, meanEI, maxEI, and ratio were higher in the classic PTC variants (n = 4) than in the other PTC variants (n = 5; p < 0.02) and in non-PTC tumors (n = 12; p < 0.005). Intra- and inter-observer coefficients of variations for meanEI in nodules were 23% and 26%, respectively. The French Thyroid Imaging Reporting and Data System score, the American Thyroid Association US classification, and the EU-Thyroid Imaging Reporting and Data System were not associated with malignancy. CONCLUSIONS: Despite high elasticity values in classic PTC variants, conventional SWE indexes failed to discriminate between benign and malignant tumors in thyroid nodules with IC.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Bardet S, Ciappuccini R, Pellot-Barakat C, et al. Shear Wave Elastography in Thyroid Nodules with Indeterminate Cytology: Results of a Prospective Bicentric Study. Thyroid. 2017. PMID: 28982296. doi:10.1089/thy.2017.0293

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。