文献速递甲状腺疾病

18F-氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描可能排除超声可疑且闪烁显像功能低下的甲状腺结节中的恶性,并减少不必要的甲状腺手术

18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography May Exclude Malignancy in Sonographically Suspicious and Scintigraphically Hypofunctional Thyroid Nodules and Reduce Unnecessary Thyroid Surgeries.
PubMed 文献 · Thyroid · 2017-09-15

回顾性分析65例超声可疑且99mTc-高锝酸盐闪烁显像功能低下的甲状腺结节(直径>1 cm)患者,均行FDG-PET/CT。FDG-PET/CT检测恶性的敏感性100%、特异性87%、阳性预测值61%、阴性预测值100%。结论认为无病理性FDG摄取可能有助于避免不必要的甲状腺手术。

要点

  • FDG-PET/CT对超声可疑且闪烁显像功能低下的甲状腺结节检测恶性阴性预测值100%。
  • 阳性预测值61%,病理性FDG摄取者应行手术。
  • 无病理性FDG摄取可能避免不必要的甲状腺手术。

核心结论

  • FDG-PET/CT可对超声可疑且闪烁显像功能低下的甲状腺结节进行风险分层,阳性预测值61%、阴性预测值100%。
  • 可疑甲状腺结节中无 visually pathological FDG 摄取可能有助于避免不必要的甲状腺手术。

研究设计与样本

  • 回顾性分析65例超声可疑且99mTc-高锝酸盐闪烁显像功能低下的甲状腺结节(直径>1 cm)患者,均行FDG-PET/CT。
  • 根据FDG-PET/CT结果,病理性FDG摄取者行甲状腺手术,非病理性FDG摄取者行随访检查。
  • 比较终点为组织学结果或至少五年的超声随访检查。

主要发现

  • 18/65(28%)患者PET/CT显示可疑甲状腺结节 visually pathological FDG 摄取(SUVmax 7.1 ± 4.6)。
  • FDG阳性结节中TIRADS 4a为3/18(17%)、4b为11/18(61%)、4c为3/18(17%)、5为1/18(6%)。
  • 无病理性FDG摄取的结节中TIRADS 4a为24/47(51%)、4b为18/47(38%)、4c为5/47(11%)。
  • 23例患者(18例FDG阳性、5例FDG阴性)接受手术,其余患者随访至少五年稳定作为替代终点。
  • FDG-PET/CT检测恶性的敏感性、特异性、阳性预测值、阴性预测值分别为100%、87%、61%、100%。

关键数值与推荐

  • FDG-PET/CT在可疑甲状腺结节中检测恶性的敏感性100%、特异性87%、阳性预测值61%、阴性预测值100%。

临床怎么用

  • 作者认为,可疑甲状腺结节中无 visually pathological FDG 摄取可能有助于避免不必要的甲状腺手术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to evaluate whether 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) is useful in the further characterization of sonographically suspicious and scintigraphically hypofunctional thyroid nodules. METHODS: Sixty-five patients with sonographically suspicious thyroid nodules that were hypofunctional on 99m-Tc-pertechnetate scintigraphy (diameter >1 cm) were retrospectively analyzed. All patients underwent evaluation with FDG-PET/CT. Thyroid nodules were sonographically categorized by Thyroid Image Reporting and Data System (TIRADS) criteria. FDG uptake in the thyroid nodules was visually compared to the remainder of the thyroid tissue and categorized as pathological or non-pathological. In cases of pathologically increased uptake, maximum standardized uptake values (SUVmax) of the suspicious nodule and the perinodular thyroid tissue were determined. Depending on the results of the FDG-PET/CT, patients underwent thyroid surgery (pathological FDG uptake) or follow-up examinations (non-pathological FDG uptake). The endpoints for comparison with the FDG uptake were either histological results or sonographic follow-up examinations of at least five years. RESULTS: In 18/65 (28%) patients, PET/CT showed visually pathological FDG uptake in the suspicious thyroid nodules (SUVmax 7.1 ± 4.6). Of these nodules, 3/18 (17%) were sonographically categorized as TIRADS 4a, 11/18 (61%) nodules as TIRADS 4b, 3/18 (17%) nodules as TIRADS 4c, and 1/18 (6%) nodule as TIRADS 5. The other nodules without pathological FDG uptake were categorized as TIRADS 4a in 24/47 (51%) patients, as TIRADS 4b in 18/47 (38%), and as TIRADS 4c in 5/47 (11%) patients. Twenty-three patients (18 FDG positive, 5 FDG negative) underwent surgery. The other patients underwent follow-up examinations with stability on observation over at least five years as a surrogate endpoint. Taking into consideration that FDG-PET/CT was rated as true negative in 42/47 patients with stability on sonographic follow-up, sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET/CT in detecting malignancy in the suspicious thyroid nodules were 100%, 87%, 61%, and 100%, respectively. CONCLUSION: FDG-PET/CT allows stratification of patients with sonographically suspicious and scintigraphically hypofunctional thyroid nodules with a positive predictive value of 61% and negative predictive value of 100%. The absence of visually pathological FDG uptake in suspicious thyroid nodules may be useful for avoiding unnecessary thyroid surgery.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Ruhlmann M, Ruhlmann J, Görges R, et al. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography May Exclude Malignancy in Sonographically Suspicious and Scintigraphically Hypofunctional Thyroid Nodules and Reduce Unnecessary Thyroid Surgeries. Thyroid. 2017. PMID: 28793848. doi:10.1089/thy.2017.0026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。