妊娠期糖尿病女性自我血糖监测依从性差与记录可靠性低常见,且可能与不良妊娠结局相关
该前瞻性研究纳入91例新诊断妊娠期糖尿病女性,评估自我血糖监测(SMBG)依从性与血糖记录本可靠性及其相关因素和妊娠结局。仅61.5%完成≥80%所需检测,依从性差与糖尿病家族史、社会剥夺及非欧洲来源相关;依从性差者子痫前期更多(12.2% vs 1.9%,P=0.049),餐后检测时间不当与分娩时HbA1c更高相关。作者建议照护者系统检查血糖仪记忆以改善管理。
要点
- 仅61.5%的妊娠期糖尿病女性完成≥80%所需SMBG检测。
- 依从性差与糖尿病家族史、社会剥夺及非欧洲来源相关。
- 依从性差者子痫前期发生率为12.2% vs 1.9%(P=0.049)。
核心结论
- 尽管妊娠期糖尿病女性被认为高度积极,但SMBG依从性与可靠性令人担忧,且可能与不良妊娠预后相关,提示照护者应系统检查血糖仪记忆以改善妊娠期糖尿病管理。
研究设计与样本
- 前瞻性选取新诊断妊娠期糖尿病、转诊至本糖尿病管理项目并理解SMBG原理的法语女性,在下次随访时收集血糖仪与记录本的SMBG结果并分析妊娠结局。
- 数据在91例女性中分析,时间为13±3天。
主要发现
- 仅61.5%的女性完成≥80%的所需检测;依从性差与糖尿病家族史、社会剥夺及非欧洲来源相关。
- 餐前与餐后检测平均间隔为141±20分钟,46.5%的女性在餐后100-140分钟完成≥80%的餐后测量;时间不当与种族及基线HbA1c较高相关。
- 23.1%的女性记录本与血糖仪记忆匹配值<90%,一致性差与糖尿病家族史相关。
- 依从性差与更多子痫前期相关(12.2% vs 1.9%,P=0.049)。
- 餐后检测时间不当与分娩时HbA1c更高相关(5.3±0.4% vs 5.0±0.3%[34±2 vs 31±2 mmol/mol],P<0.01),尽管胰岛素治疗更频繁。
临床怎么用
- 作者建议照护者应系统检查血糖仪记忆以改善妊娠期糖尿病管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the compliance with self-monitoring of blood glucose (SMBG) and the reliability of diabetes logbooks in women with gestational diabetes mellitus (GDM), as well as the associated determinants and outcomes. RESEARCH DESIGN AND METHODS: We prospectively selected French-speaking women with newly diagnosed GDM who had been referred to our diabetes management program and understood SMBG principles. At the next follow-up visit, we collected SMBG results from glucose meters and logbooks. We analyzed pregnancy outcomes. RESULTS: Data were analyzed over 13 ± 3 days in 91 women. Only 61.5% had performed ≥80% of the required tests. Poor compliance was associated with a family history of diabetes, social deprivation, and non-European origin. The average time between pre- and postprandial tests was 141 ± 20 min, with 46.5% of women performing ≥80% of postprandial measurements 100-140 min after meals. Inadequate timing was associated with ethnicity and higher HbA1c at baseline. A total of 23.1% of women had <90% matched values in diary and meter memory, and a poor concordance was associated with a family history of diabetes. Poor adherence was associated with more preeclampsia (12.2 vs. 1.9%, P = 0.049), and inadequate postprandial test timing with a higher HbA1c at delivery (5.3 ± 0.4 vs. 5.0 ± 0.3% [34 ± 2 vs. 31 ± 2 mmol/mol], P < 0.01), despite more frequent insulin therapy. CONCLUSIONS: Although women with GDM are considered to be highly motivated, SMBG adherence and reliability are of concern and may be associated with poor gestational prognosis, suggesting that caregivers should systematically check the glucose meter memory to improve GDM management.
引用
- Cosson E, Baz B, Gary F, et al. Poor Reliability and Poor Adherence to Self-Monitoring of Blood Glucose Are Common in Women With Gestational Diabetes Mellitus and May Be Associated With Poor Pregnancy Outcomes. Diabetes Care. 2017. PMID: 28724718. doi:10.2337/dc17-0369