负荷后1小时与2小时血浆葡萄糖浓度对西南部原住民2型糖尿病的预测作用相当
该纵向流行病学研究纳入1965至2007年无糖尿病的成人志愿者(以西南部原住民为主),基线行75 g OGTT测1 h-PG,部分组行IVGTT及高胰岛素-正葡萄糖钳夹测急性胰岛素反应(AIR)和胰岛素刺激的葡萄糖处置(M),并随访2型糖尿病发生。结果显示1 h-PG与AIR关联更紧密、2 h-PG与M关联更紧密,二者预测2型糖尿病能力相似;1 h-PG切点9.3 mmol/l的敏感性与特异性与2 h-PG切点7.8 mmol/l相似。
要点
- 1 h-PG与AIR的关联(r=-0.384)较2 h-PG(r=-0.281)更紧密。
- 2 h-PG与M的关联(r=-0.408)较1 h-PG(r=-0.340)更紧密。
- 1 h-PG切点9.3 mmol/l与2 h-PG切点7.8 mmol/l的敏感性和特异性水平相似。
核心结论
- 1 h-PG与2型糖尿病的重要生理预测指标相关,预测2型糖尿病的效果与2 h-PG相当,可作为识别2型糖尿病风险升高个体的替代方法。
研究设计与样本
- 分析纳入1965至2007年纵向流行病学研究中无糖尿病的成人志愿者,以西南部原住民为主,基线OGTT包含1 h-PG测量。
- Group 1(n=716)接受IVGTT和高胰岛素-正葡萄糖钳夹,分别测AIR和M。
- Group 1中490/716例及更大的Group 2(n=1946)接受随访以评估2型糖尿病发生,中位随访分别为9.0年和12.8年。
主要发现
- 1 h-PG与AIR的关联(r=-0.384)较2 h-PG(r=-0.281)更紧密。
- 2 h-PG与M的关联(r=-0.408)较1 h-PG(r=-0.340)更紧密。
- 1 h-PG与2 h-PG预测2型糖尿病的能力相似,二者同时纳入模型后该能力未改变。
- 1 h-PG切点9.3 mmol/l提供的敏感性和特异性水平与2 h-PG切点7.8 mmol/l相似,后者用于定义糖耐量受损。
关键数值与推荐
- 1 h-PG切点9.3 mmol/l与2 h-PG切点7.8 mmol/l的敏感性和特异性水平相似。
- 2 h-PG切点7.8 mmol/l用于定义糖耐量受损,后者是公认的2型糖尿病预测指标。
临床怎么用
- 作者认为1 h-PG是识别2型糖尿病风险升高个体的替代方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS/HYPOTHESIS: Elevated 2-h plasma glucose concentration (2 h-PG) during a 75 g OGTT predict the development of type 2 diabetes mellitus. However, 1-h plasma glucose concentration (1 h-PG) is associated with insulin secretion and may be a better predictor of type 2 diabetes. We aimed to investigate the association between 1 h-PG and 2 h-PG using gold standard methods for measuring insulin secretion and action. We also compared 1 h-PG and 2 h-PG as predictors of type 2 diabetes mellitus. METHODS: This analysis included adult volunteers without diabetes, predominantly Native Americans of Southwestern heritage, who were involved in a longitudinal epidemiological study from 1965 to 2007, with a baseline OGTT that included measurement of 1 h-PG. Group 1 (n = 716) underwent an IVGTT and hyperinsulinaemic-euglycaemic clamp for measurement of acute insulin response (AIR) and insulin-stimulated glucose disposal (M), respectively. Some members of Group 1 (n = 490 of 716) and members of a second, larger, group (Group 2; n = 1946) were followed-up to assess the development of type 2 diabetes (median 9.0 and 12.8 years follow-up, respectively). RESULTS: Compared with 2 h-PG (r = -0.281), 1 h-PG (r = -0.384) was more closely associated with AIR, whereas, compared with 1 h-PG (r = -0.340), 2 h-PG (r = -0.408) was more closely associated with M. Measures of 1 h-PG and 2 h-PG had similar abilities to predict type 2 diabetes, which did not change when both were included in the model. A 1 h-PG cut-off of 9.3 mmol/l provided similar levels of sensitivity and specificity as a 2 h-PG cut-off of 7.8 mmol/l; the latter is used to define impaired glucose tolerance, a recognised predictor of type 2 diabetes mellitus. CONCLUSIONS/INTERPRETATION: The 1 h-PG was associated with important physiological predictors of type 2 diabetes and was as effective as 2 h-PG for predicting type 2 diabetes mellitus. The 1 h-PG is, therefore, an alternative method of identifying individuals with an elevated risk of type 2 diabetes mellitus.
引用
- Paddock E, Hohenadel MG, Piaggi P, et al. One-hour and two-hour postload plasma glucose concentrations are comparable predictors of type 2 diabetes mellitus in Southwestern Native Americans. Diabetologia. 2017. PMID: 28664298. doi:10.1007/s00125-017-4332-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。